WIRING
Note: This range hood must be properly
grounded. The unit should be installed by
a qualified electrician in accordance with
all applicable national and local electrical
codes.
1. Remove the wiring box cover. Remove
a knockout from the wiring box (Fig.21).
2. Secure the supply wire to the wiring
box with an appropriate connector.
3. Make electrical connections. Connect
white to white, black to black and green
to green.
4. Replace wiring box cover and screws.
Make sure that wires are not pinched
between cover and box.
EXTERNAL BLOWER
WIRING
1. Run 2-wire plus ground power cable
from the exterior blower to the hood's
wiring box marked "motor connection"
(Fig.22).
2. Remove the cover from the wiring box
and remove one knockout.
3. Feed 6" of cable through the knockout
opening and secure the cable to the
wiring box with an appropriate
connector.
4. Make electrical connections at the hood.
Connect white-to-white, red-to-black
and green-to-ground.
5. Replace the wiring box cover and
screws. Make sure wires are not
pinched between the cover and box.
Exterior blower connection:
1. Make electrical connections at the
exterior blower (see instructions
provided with the exterior blower).
FIGURE 21
WIRING BOX
COVER
FIGURE 22
CONNECT:
WHITE-TO-WHITE,
RED-TO-BLACK,
GREEN-TO-GROUND.
BOX MARKED
"MOTOR
CONNECTION"
- 12 -
EXTERIOR BLOWER
OR "IN-LINE"