Interruption Of Work Till 4 Hours; Taking Out Of Operation And Cleaning; Maintenance - WAGNER W 600 Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

W 600
W hen coating material builds up on the nozzle and air cap, clean both parts with a
solvent or water .

Interruption of Work till 4 Hours

T urn the machine off .
I nsert the spray gun into the gun holder .
W hen processing 2-component varnishes, clean the device immediately .

taking Out of Operation and Cleaning

Proper cleaning is the prerequisite for problem-free operation of the paint application
device. No warranty claims are accepted in case of improper or no cleaning.
1) Turn the machine off . Vent the container in case of longer breaks and after the work
has been terminated . This can be done by briefly turning open and then closing the
container or by pulling the trigger and letting the paint into the original paint container .
2) Unscrew the container . Empty any remaining coating material back into the material tin .
3) Preclean the container and feed tube with a brush . Clean the ventilating bore (Fig .   11, A) .
4) Pour solvent or water into the container . Screw the container back on .
Do not use flammable materials for cleaning purposes.
5) Turn on the machine and spray the solvent or water into a container or a cloth .
6) Repeat the above procedure until the solvent or water emerging from the nozzle is clear .
7) Turn off the machine .
8) Screw of the container and empty it . Pull out the suction tub with container seal .
CAUtION! Never clean seals and nozzle or air holes of the spray gun with metal
objects .
9) Unscrew the union nut and remove the air cap and nozzle . Clean the air cap, nozzle
seal and nozzle with a brush and solvent or water (Fig . 11, 5) .
10) Clean the outside of the spray gun and container with a cloth soaked in solvent or water .
11) Assemble the parts again (see "Assembly") .
Assembly
Slide the nozzle seal (Fig . 10 1) with the groove (slot) facing forwards into the nozzle
(Fig . 10 2) . Put the nozzle onto the gun body and find the correct position by turning it .
Put the air cap onto the nozzle and tighten it using the union nut .
Place the container seal from below on the suction tube and slide it over the collar, while
turning the container seal slightly . Insert the suction tube with container seal in the gun
body .

Maintenance

Change the air filter if it is soiled . For this pull the air filter out of the unit (Fig . 9) . Insert a
new air filter .
WARNING! Never operate the machine without the air filter; dirt could be sucked in
GB
31

Publicidad

Tabla de contenido
loading

Tabla de contenido