Chemical conditioners:
Products that can be purchased from
our Authorized Technical Assistance
network
LIFE PLUS
LIFE DUE
BIO KILL
PROGLI
Products with equivalent characteristics may be used
The unit is equipped with a frost protection system that activates the boiler in hea-
ting mode when the system delivery water temperature falls below 6°C. The device
is not active if the power and/or gas supply to the unit is turned off. If necessary,
for system protection use a suitable antifreeze liquid that meets the same require-
ments as set out above and provided for by UNI 8065.
In the presence of adequate chemical/physical system and feed water treatments
and related high cyclicity controls able to ensure the required parameters, for in-
dustrial process applications the product can be installed in open-vessel systems
with vessel hydrostatic height able to ensure compliance with the minimum opera-
ting pressure indicated in the product technical specifications.
Failure to comply with the above regulations will result in non-recognition of
the warranty.
To ensure the reliability and proper operation of the boilers, install a mechani-
cal filter in the loading circuit and a sludge remover/de-aerator in the system.
Antifreeze system, antifreeze fluids, additives and inhibitors
The boiler is equipped with an antifreeze system that turns on the boiler in heating mode when the system delivery water
temperature falls under 6°C. The device will not come on if the electricity and/or gas supply to the unit are cut off. If it be-
comes necessary, it is permissible to use antifreeze fluid, additives and inhibitors only if the manufacturer of these fluids
or additives guarantees they are suitable for this use and cause no damage to the heat exchanger or other components
and/or materials of the boiler unit and system. It is prohibited to use generic antifreeze fluid, additives or inhibitors that are
not expressly suited for use in heating systems and compatible with the materials of the boiler unit and system.
208
Alternative products
X100
X200
X700
X500
cod. 3541Q760 - Rev. 00 - 02/2019
FORCE W
Description
General protection
Noise reduction
Sanitizing and biocidal
General protection and frost protection