Setting Mode Table - Citizen CD-S500 Serie Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Setting Mode Table

Soft Control-SW
Set item
Initial value
Command Type
EPSON
Number of Col.
40/33
Font Select
7x9
Paper Plies
OFF
Paper End
ENB
Paper Near-End
ENB
Slashed Zero
OFF
Print Direct.
BI-DIR
Auto LF
OFF
Code Page
437
Setting value
EPSON
The emulation is selected from EPSON/STAR/
STAR
CBM1/CBM2.
CBM1
CBM2
Number of full dot in full column is 200 dots. For the
40/33
number of line columns based on the paper width, see
42/35
"Setting the Paper Width and Printing Line Column Number".
7Ω9
The initial font size is selected immediately after the
power is turned on.
9Ω9
Copy mode is selected.
OFF
OFF/2P/3P can be selected. But when 3P is set, the
2P
printing speed is low.
3P
ENB
The PE signal enabled/disabled is set at paper end when
DIS
only the centro-interface is set as enabled. During
enabled status, BUSY, PE, FAULT are output and printing
stops at paper out. During disabled status, only BUSY is
output and printing stops at paper out.
ENB
The PE signal enabled/disabled is set at paper near end
when only the centro-interface is set as enabled. During
DIS
enabled status, PE, FAULT are output and printing
continues. During disabled status, nothing is output and
printing continues.
OFF
It sets whether or not slash is used with the numeral 0
(zero).
ON
Designates printing direction. When BI-DIR is selected,
BI-DIR
UNI-DIR
printing starts from the closer of the left and right ends
of the next printing line from the print stop location.
During UNI-DIR printing is usually done from the left end.
OFF
The LF operation during CR code reception is selected.
When ON, LF does not operate; when OFF, LF operates.
ON
CR: Carriage Return LF: Line Feed
437,
The code page is selected.
KATAKANA,
850, 860
863, 865
852, 866
857, 858
WPC1252
Remarks
English
37

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cd-s500a

Tabla de contenido