4 Startup mode manual
If your equipment does not have an electrical startup or if it is available but the
battery doesn't have enough charge, the generator can startup manually with
the starter rope.
Check that the gasoline valve is in the "ON" position as per point 1 on page 11.
Check that the choke is to the left in the "CHOKE" position as per point 2 of
page 11.
Pull the startup handle slowly and until the end to calculate the maximum length
of the rope (and do not exceed it later when pulling vigorously), then allow the
rope to coil back.
Pull softly again until you notice slight resistance, now allow the rope to coil
back and pull vigorously to start up the engine.
If you were unable to start up in the first try, repeat the operation.
NOTE: If you reach the end of the rope length abruptly you could damage
the handle or rope spring and it wouldn't be covered by warranty.
NOTE: Do not let go of the handle after pulling to prevent the handle from
hitting the machine. Move your hand along with the handle until it has coiled
back completely.
6 Once started wait for a few seconds and then turn the choke lever to the right
"RUN" (open air position). The engine will begin working stably and will be
ready to have equipment plugged into it.
STARTUP HANDLE
13