Features:
ducting outlet diameter: 2x80 mm
maximum recommended ducting length 2m
it is not possible to thermostat the ducting
possibility to adjust the fan speed in percentage
ADDITIONAL THERMOSTAT FOR DUCTING MOTOR CONTROL
For models with ducting motor there is also the possibility of thermostatting the motor itself. The connection of an external thermostat will
allow to control the ducting motor independently from stove functioning.
At this point just set the desired temperature on the thermostat; the thermostat will control the functioning of the second motor:
with temperature to be reached (closed contact) the second motor will follow the trend of
the stove.
when the temperature has been reached (open contact), it takes the ducting motor to 1st
speed and will be displayed by the ashing LED relating to the ducting motor.
The ducting thermostat clamp is tted with a jumper as standard.
See the example drawing to the side.
REARMS
The gures below illustrate the positions of the tank (85°C) rearms. Contact the quali ed technician if one of the rearms should be triggered,
so as to verify the cause.
ENGLISH
45