Routine Maintenance Carried Out By Authorised Technicians; Putting The Equipment Out Of Service End Of The Season - Dal Zotto BEATRICE Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

ROUTINE MAINTENANCE CARRIED OUT BY AUTHORISED TECHNICIANS

Routine maintenance must be performed at least once a year.
As the generator uses pellets as solid fuel, it needs an annual routine maintenance interval that needs to be performed by an authorised
Technician by only using original spare parts.
Failure to do so can a ect the appliance's safety and you may no longer be entitled to the warranty conditions.
By following the cleaning schedule reserved to the user and reported in the user and maintenance manual, one ensures correct combustion
in the generator over time, thereby preventing any anomalies and/or malfunctions that may require more work to be performed by the
technician. Requests for routine maintenance are not covered by the product's warranty.
DOOR, ASH DRAWER AND BURN POT GASKETS
The gaskets ensure the tightness of the stove and its consequent proper operation.
They must be checked periodically: in the event they are worn or damaged they must be replaced immediately.
These operations must be carried out by a quali ed technician.
CONNECTION TO THE FLUE
Vacuum and clean the pipe that leads to the ue yearly or whenever necessary. If there are horizontal sections, any residue must be removed
before it obstructs the ue.

PUTTING THE EQUIPMENT OUT OF SERVICE END OF THE SEASON

At the end of every season, before turning o the stove, we recommend completely emptying the pellet tank and using a vacuum cleaner to
clear up any pellets and dust residue inside it.
You should also disconnect the generator from the mains and, to ensure greater safety especially if there are any children around, remove the
power supply cable.
Routine maintenance must be performed at least once a year.
IF THE POWER SUPPLY CABLE IS DAMAGED, IT MUST BE REPLACED BY THE AFTER SALES SERVICE OR BY A SIMILARLY
QUALIFIED PERSON, SO AS TO AVOID ALL RISKS.
A
Fumes motor (disassembly and cleaning and fumes pipe), new silicone in required points
B
Inspection of gaskets, ash drawer and burn pot door (replace them and apply silicone where required)
C
Combustion chamber (total cleaning of the entire chamber) and ignition plug pipe cleaning
D
Tank (complete emptying and cleaning)
E
Room air fan disassembly and removal of dust and any pellet debris
F
Air intake pipe inspection and any ow sensor cleaning