ELECTRICAL CONNECTION

The appliance is equipped with an electrical cable H05RR-F 3x0.75 mm² having an
European plug. It is a type "Y" connection and therefore any replacement of the cable
must be carried out by a qualified staff only. Feeding 1N 230V AC 50Hz. The electrical
cable should be disposed in such a way to avoid any contact with hot and sharp parts.
The appliance should be connected with a grounding system.

FEED AIR COMBUSTION DIRECT FROM ENVIRONMENT

It's advisable to read, follow and respect what indicated in the paragraphe 1.1
The equipment should have the necessary air for combustion, supplied by external air
intake.
The air intake should have the following characteristics :
a)
Total free section min 200 cm²;
b)
Connected directly with installation environment ;
c)
Protected with grate or lath ( attention to not reduce the min. section required on
point a ) and placed so that to avoid obstruction.
The air inflow can be also supplied from the adjacent room but the air intake should be
always free and connecter ahead outside. No chimney or suction hood should be present
in the environment of installation or into the nears ones.
Inside the adjacent room the air intake should have the characteristics required in letter a
and c .
The adjacent room can not be use as garage, warehouse of combustible material etc..

FEED AIR COMBUSTION DIRECT FROM OUTSIDE

It's advisable to read, follow and respect what indicated in the paragraphe 1.1
To take air direct from outside it's necessary :
Use metal tubes of diameter Ø50 mm or more; resistant to temperature of al least
200°C in this area of connection to the appliance.(See the connection schedule).
To guarantee a sufficient air influx, the connection's tube has not to be longer that
2÷3 mt. and it has not to have a lot of curves.
If the air intake is direct to outside, its output has a curve of 90° down with a
protection grill to avoid the introduction of small animals.
In case of closure device, it must open automatically at equipment's starting.
To not observe these instructions, it means that Your stove will have a bad
combustion and the lost of Your guarantee.
Protected with grate or lath ( attention to not reduce the min. section required on
point a ) and placed so that to avoid obstruction .
NOTE: The air inflow whole must be placed at the low.
NOTE : Extractor fans when operating in the same room or space as the appliance may cause
problems.
NOTE :The installation room should not be put in pressure by other appliances such as
suction hoods, chimneys, evacuation flues, present in the room itself or in the adjacent rooms,
which are in communication.