Defining System Components In Fronius Solar Net; General; Setting The Address On The Inverter; Setting The Address On Datcom Components - Fronius DATCOM Compact Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Defining system components in Fronius Solar Net

General

Fronius Solar Net will recognize different DATCOM components automatically (datalogger,
sensor card, etc.). However, there is no automatic distinction between several identical
DATCOM components. For this reason, each system component must have an individual
number (address) to uniquely identify each system component in Fronius Solar Net (invert-
er or DATCOM component).
Fronius inverters give you the option to set the address directly on the display. However,
some versions of Fronius IG are not equipped with a display. In this case, the address can
be set via two keys.
DATCOM components are equipped with a special setting wheel for addresses. A small
screwdriver is required for this.
Setting the ad-
Please see the inverter operating instructions for setting the inverter address.
dress on the in-
verter
Setting the ad-
Proceed as follows for all DATCOM components (whether card or box):
dress on DAT-
COM components
1
Example:
-
-
Turn the setting wheel (1) to the desired address using a screwdriver
(1)
NOTE! Two identical devices should never have the same address in a network.
Permitted:
Fronius IG „Adress 1", Sensor Card „Adress 1"
Not permitted:
Fronius IG 20 „Adress 1", Fronius IG 30 „Adress 1"
IMPORTANT! You do not have to set the
address for the datalogger because there is
always only one datalogger per system.
17

Publicidad

Tabla de contenido
loading

Tabla de contenido