Connection
These hobs are delivered with type H 05 VVF power cable (1.5mm²) with 3/5 conductors (including a
green/yellow earth wire), which must be connected to the power supply via a plug that complies with
publication CEI 83 or an all-pole cut-out unit with contacts that open by at least 3mm.
If the cable is damaged, it must be replaced by the manufacturers, their After Sales Service or another
similarly qualified person for avoiding any possible risk of accident.
When connected to 400 V2N three-phase, if you hob malfunctions, check that the neutral cable is pro-
perly connected.
The unit must be installed so that the mains plug is easily accessible.
fuse : 32 Amp
Blue
Brown
L
N
230 V
fuse : 16 Amp*
Blue
Brown
15:19
Page 15
Installing your hob in complete safety
Brown
Green/yellow
Blue
Black
230 V
Green/yellow
15
fuse : 16 Amp
Green/yellow
NOTE
Separate the 2
phase wires L1
and L2 before
L2
connecting
N L1
230 V
230 V
220-240 V∼ ∼ 50 Hz
Total energy consumption:
DTV301.......3,4 kW
DTV303.......7 kW
DTV304.......6,2 kW
DTV305.......6,9 kW
DTV306.......7 kW
Black