Technical data
6.1
Accuracy
The specifications are typical values at 24 V DC and room
temperature, with a nominal length of 500 mm in
conjunction with the BTL-P-1013-4R, BTL-P-1013-4S,
BTL-P-1012-4R or BTL-P-1014-2R magnet.
The BTL is fully operational immediately, with full accuracy
after warm-up.
Resolution:
Position
adjustable via SDO in
increments of 5 µm
Movement speed
adjustable via SDO in
increments of 0.1 mm/s
Sampling rate f
Standard
Non-linearity
Hysteresis
Repeat accuracy
Temperature coefficient
1)
6.2
Ambient conditions
Ambient temperature
Storage temperature
Relative humidity
Pressure rating (when
installed in hydraulic
cylinders)
at Ø 8 mm
at Ø 10.2 mm
Shock rating
Continuous shock
per EN 60068-2-27
3), 4)
Vibration
per EN 60068-2-6
3), 4)
Degree of protection as per
IEC 60529 when threaded
together
www.balluff.com
5 µm
0.1 mm/s
500 Hz
±30 µm
≤ 1 LSB
±1 LSB
(6 µm + 5 ppm x nominal
length)/K
2)
– 40 °C...+ 85 °C
– 40 °C...+ 100 °C
< 90%, non-condensing
≤ 250 bar
≤ 600 bar
100 g/6 ms
100 g/2 ms
12 g, 10 ...2000 Hz
IP67
6.3
Supply voltage (external)
Stabilized voltage
5)
Residual ripple
Current draw
Inrush current
Reverse polarity protection
Overvoltage protection
Dielectric strength of
GND to housing
6.4
Control signals
CAN_L, CAN_H, CAN_GND in accordance with
CiA
DS 301.
®
Each change in status of the 4 cams is
transferred as an emergency object with the
highest priority after < 0.5 ms! This BTL is
therefore suitable for especially time-critical
control operations.
6.5
Dimensions, weights
Rod diameter
Nominal length
at Ø 8 mm
at Ø 10.2 mm
Weight (depends on length) Approx. 2 kg/m
Housing material
Flange material
Rod material
Rod wall thickness
at Ø 8 mm
at Ø 10.2 mm
Housing mounting via
threads
Nominal length 500 mm, magnet in the middle of the measuring range
1)
For
: Use in enclosed spaces and up to an altitude of 2000
2)
sea level.
Individual specifications as per Balluff factory standard
3)
Resonant frequencies excluded
4)
For
: The BTL must be connected externally to a power-limited circuit
5)
according to IEC
61010 or a power source of limited output according to
IEC
60950 or a power supply with Protection Class
or CEC.
20...28 V DC
24 V ±2 V
ss
< 100 mA
≤ 3 A
yes
yes
500 V DC
8 mm or 10.2 mm
25...1016 mm
25...4000 mm
Aluminum
Stainless steel
Stainless steel
0.9 mm
2 mm
M18×1.5 or 3/4"-16UNF
m above
2 according to NEC
english
15