Instalhttion
Types
This ice maker has been designed
for Mobile (free-standing)
installation.
It can also be
Enclosed (as under a cabinet) or Built-in (sealed to the floor), although this last option is
not the preferred
method of installation.
In every case, there must be adequate air space
around the unit for ventilation
purposes (see diagrams on page 8).
Mobile Installation:
A mobile installation
will allow you to install the icemaker free-standing
in any place you
desire provided
you have access to a water supply and drainage
facilities.
You must
follow the stated instructions
for
a. Electrical requirements
b. Water supply and drain connections
c. Leveling the icemaker.
Enclosed
Installation:
An enclosed
installation
will allow you to install the ice maker under a cabinet,
or in a
kitchen cabinet provided the required
clearance
space around the ice maker is respected.
This installation
has the same requirements
as a mobile installation.
The unit should be placed in the cabinet by sliding it into the cabinet's
opening and then
leveling it properly.
IMPORTANT."
For Mobile
and
Enclosed
installations
you
must
use flexible
water
and
drain
connections
to the water
supply
and drain.
This
will allow
the moving
of the ice
maker
for
cleaning.
Use
the water
and
drain
hoses
supplied
with
the unit for
these
connections.
Built-in
Installation:
If this
method
of installation
is chosen,
it will
still
be necessary
to allow
adequate
ventilation
space around
the unit. The following
additional
items
must be observed.
1. Place the ice maker in front of the installation
location.
Remove the feet and place
the unit flat on the floor or on a platform depending on your installation
requirements.
2. The water supply line and drain line must be plumbed
before connecting
to the ice
maker.
3. Turn on the main water supply and tap. Check for water supply connection
leaks.
Tighten any connections
(including
connections
at the valve) or nuts that leak.
4. Pour 1 gallon of water into the ice storage bin to check for leaks at all drain connec-
tions and the nut of the drain water hole. Tighten any connections
or nuts that leak.
(This procedure
will also indicate if the drainpipe is kinked or pinched.)
13