12.2 Electric Lock Connection
12.2.1 Door Lock Controlled with Internal Power
Note:
1. Electronic lock fail secure type
should be used.
2. The door lock is limited to 12Vdc,
and holding current must be less
than 250mA.
3. The door lock control is not timed
from the Exit Button (EB).
4. T h e l o c k - r e l e a s e m u s t b e
confi gured as a normal operating
lock-release. See chapter 11.2.
5. When connect in Electronic lock,
put the jumper in position in 1-2.
12.2.2 Door Lock Controlled with potential free relay
Note:
1. Use an external power supply (PSU)
according tothe electrical lock's
consumption.
2. The jumper must be taken off before
connecting.
3. Establish the connected lock-release
mode (See chapter 11.2):
• Normal open realay type:
Unlock Mode = 0 (by default).
• Normal closed relay type:
Unlock Mode = 1.
1 2 3
1 2 3
connect Electronic lock, the jumper position in 2-3.
BUS
PL
S+
EB
*
Exit
Button
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
An intermediate relay should be
1 2 3
1 2 3
connected for equal or higher
connect Electronic lock, the jumper position in 2-3.
voltages of 20V, otherwise the panel
will be damaged.
BUS
PL
EB
*
Exit
Button
For installations with a motorized door, please
follow this method of connection.
1 2 3
Take off the Jumper
BUS
PL
S +
POWER
SUPPLY
S-
LOCK
S+
S-
LOCK
relay
S-
LOCK
1-2.
-12-