11.2 How to set the unlock parameter
Door-lock type:
There are two operating modes:
1. Normal Lock-release:
This allows you to open the door for the time that the lock-release is powered.
2. Inverse Lock-release:
This allows you to open the door for the time that the lock-release is not powered.
Enter code 8010 if the lock-release is to operate normally.
Enter code 8011 if the lock-release is to operate inversely.
Unlock time:
The unlock time can be changed by yourself at any time. It can be set from 1 to 99
seconds.
The code number from 8401 to 8499 are used to set the unlock time to 1~ 99 seconds.
12. System Wiring
12.1 System Wiring
12.1.1 One Way Connection
Doorbell Button
Switch
AC~
PC6
BUS(IM) BUS(DS)
BUS (M)
BUS (DS)
Monitor
Panel
L1 L2 PL S+ S-
-
+