In the charts following the single available functions are described in the plant.
MENU
Automatic closure time. It is enabled only with "TCA"=ON logic.
TCA
At the end of the preset time, the control unit controls a closure operation.
The stroke time of the gate leaf is adjusted during the partial opening phase controlled
Tped
by the pedestrian input.
Braking is adjusted.
tsm
The value is expressed in percentage on the aggregate value of the stroke.
FSTS
The opening and closing speed is adjusted.
sldS
Speed during braking is adjusted.
Adjustment of amperometric sensor sensitivity in opening*
PMo
1: maximum sensibility - 99**: minimum sensibility
Adjustment of amperometric sensor sensitivity in closing*
PMC
1: maximum sensibility - 99**: minim sensibility
It is activated only with AUX1 or AUX2 parameter preset on value 2.
TLS
The activation time of the service light is adjusted.
It selects the operating mode of the AUX 1 output:
0: Open gate indicator light. The light is off when the door is closed, flashes with
moving door and is on with open door.
See wire diagram.
1: Second radio channel. The output is controlled by the radio channel of the built-in
AUX1
receiver (see RADIO Menu).
2: Service light. The contact closes for the time preset with TLS parameter. The
countdown starts at the inception of operation.
3: Area light. The contact closes in the opening phase and remains closed for the
entire TCA time. It opens only with closed door.
See wire diagram, Fig. 2.
The same operating options as AUX1 output, but referred to AUX2 terminals. See
AUX 2
connections in Fig. 3.
TBR
Stop space is adjusted after reaching the opening and closing limit switch.
It regulates the reversal space that the leaf runs as consequence a result of the safety
edge action (or triggering of the amperometric sensor).
SPIN
During the reversal phase any further action of safety edge or photocells is ignored.
This value is expressed in second.
* ATTENTION: A wrong formulation of these parameters can be dangerous.
Respect the regulations in force!
** By presetting the value at 99 before carrying out the Autotest, the control unit does perform the calculation of the torque, as
indicated in paragraph "LEARNING OF VALUES", and the amperometric sensor is disabled.
MENU
Enables or disables automatic closing
TCA
On: automatic closing enabled
Off: automatic closing disabled
Enables or disables multi-flat function.
On: multi-flat function enabled. The step-by-step and perdestrian commands have
IBL
no effect during the opening phase.
Off: multi-flat function disabled.
During the TCA phase, the PP controls are enabled or disabled.
IBCA
On: PP controls are disabled.
Off: PP controls are enabled.
PARAMETERS, LOGIC AND SPECIAL FUNCTIONS
PARAMETERS (PAR)
FUNCTION
LOGICS (LOGI)
FUNCTION
MEMO
MIN-MAX-(Default)
1-240-(40s)
5-100-(20%)
0-100-(20%)
20-99-(70)
20-99-(50)
1-99-40%)
1-99-(40%)
1-240-(60s)
0-3-(0)
0-3-(1)
1-3-(3)
1-4 (2)
DEAFULT
MEMO
(ON)
(OFF)
(OFF)
15