Beninca CP.B24ESA Manual De Uso página 17

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 36
The remote storage of the radio transmitter codes is enabled or disabled (see par.
REMOTE LEARNING).
REM
On: Enabled remote storage
Off: Disabled remote storage.
The motor checks are enabled or disabled.
On: Checks are enabled. If the checks are not successful, the door/gate will not
TSTM
move.
Off: Disabled check.
The Encoder is enabled or disabled.
On: the encoder is enabled.
Off: the encoder is enabled. Timed operation, self-learning and self-setting are not
ENC
avvilable.
If this logics is activated after being disabled, a new SELFTEST should be carried
out.
Enables or disables motor thermal protection intervention
THRM
On: enabled
Off: disabled
MENU
By selecting this function, the receiver is waiting for (Push) a transmitter code to be assigned to the step-by-step
function.
PP
Press the transmitter key, which is to be assigned to this function.
If the code is valid, it will be stored in memory and OK will be displayed.
If the code is not valid, the Err message will be displayed.
By selecting this function, the receiver is waiting for (Push) a transmitter code to be assigned to the second radio
channel.
2Ch
Press the transmitter key, which is to be assigned to this function.
If the code is valid, it will be stored in memory and OK will be displayed.
If the code is not valid, the Err message will be displayed.
When this function is selected, the receiver awaits (Push) a transmitter code to be assigned to the PED function.
Press the transmitter key, which is to be assigned to this function.
PED
If the code is valid, it will be stored in memory and OK will be displayed.
If the code is not valid, the Err message will be displayed.
By selecting this function, the receiver is waiting for (Push) a transmitter code to be erased from memory.
CLR
If the code is valid, it will be stored in memory and OK will be displayed.
If the code is not valid, the Err message will be displayed.
RTR
The memory of the receiver is entirely erased. Confirmation for the operation is asked.
Note: Transmitters ARC and Rolling-code/Fixed code cannot be stored in memory at the same time. For example, if the first
transmitter stored in memory is ARC, the following transmitters could be only ARC. Use the RTC function to completely erase the
memory should the type of transmitters be changed.
The number of cycles (open+close) completed by the system is displayed.
When the push-button <PG> is pressed once, the first 4 digits are displayed, if the push-button is pressed once more, the last 4
digits are displayed.
E.g. <PG> 0012 >>> <PG> 3456: 123.456 cycles were performed.
This function allows to activate the indication of maintenance required after a certain number of operations, preset by the installer.
To activate and select the number of operations, proceed as follows:
Press the <PG> button, OFF is displayed, indicating that the function is disabled (default).
Select one of the numbers shown (from OFF to 100) by using the <+> and <-> keys . The figures express the value of hundreds of
cycles (e.g.: the number 50 means 5000 operations).
Press OK to activate the function. The PROG message is displayed.
When the flashing light flashes for around 10 sec at end of operation, this means that maintenance operations are needed.
RESET of the control unit. WARNING: Returns the control unit to the default values.
When the <PG> push-button is pressed once, the RES wording begins to flash, if the push-button<PG> is pressed once more, the
control unit is reset.
Note: neither the transmitter codes nor the position and stroked of the gate leaf will be erased from the receiver.
RADIO (RAD)
NUMBER OF CYCLES (Nman)
MAINTENANCE (maci)
RESET (RES)
FUNCTION
(ON)
(ON)
(ON)
(ON)
17

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cp.b1024esa

Tabla de contenido