Beninca CP.B24ESA Manual De Uso página 18

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 36
The self-calibration of the triggering thresholds of the anti-crash device (amperometric sensor), as well as the stroke learning are peri -
formed. See paragraph SELF-LEARNING
It allows to type in an access protection code to the programming of the control unit.
A four-character alphanumeric code can be typed in by using the numbers from 0 to 9 and the letters A-B-C-D-E-F.
The default value is 0000 (four zeros) and shows the absence of a protection code.
While typing in the code, this operation can be cancelled at any moment by pressing keys + and – simultaneously. Once the password
is typed in, it is possible to act on the control unit by entering and exiting the programming mode for around 10 minutes in order to
allow adjustments and tests on functions.
By replacing the 0000 code with any other code, the protection of the control unit is enabled, thus preventing the access to any other
menu. If a protection code is to be typed in, proceed as follows:
- select the Code menu and press OK.
- the code 0000 is shown, also in the case a protection code has been previously typed in.
- the value of the flashing character can be changed with keys + and -.
- press OK to confirm the flashing character, then confirm the following one.
- after typing in the 4 characters, a confirmation message "CONF" appears.
- after a few seconds, the code 0000 appears again
- the previously stored protection code must be reconfirmed in order to avoid any accidental typing in.
If the code corresponds to the previous one, a confirmation message "OK" appears.
The control unit automatically exits the programming phase. To gain access to the Menus again, the stored protection code must be
typed in.
IMPORTANT: TAKE NOTE of the protection code and KEEP IT IN A SAFE PLACE for future maintenance operations. To remove
the code from a protected control unit, enter the programming mode with the password and reset the code to the 0000 default
value.
IF YOU LOOSE THE CODE, PLEASE CONTACT THE AUTHORISED SERVICE CENTER FOR THE TOTAL RESET OF THE CON-
TROL UNIT.
After any LOGIC change or control panel reset, it is necessary to perform a self-learning procedure
An optional accessory to power the control unit is available in the event the mains power supply is cut off.
The kit is composed of a battery charger and two 12V rechargeable batteries, fixing brackets, screws and cables.
For further information, please refer to instructions supplied with the accessory.
If the transmitter code is already stored in the receiver, the remote radio learning can be carried out (without accessing the control unit).
The REM logics must be ON.
IMPORTANT: The procedure should be carried out with gate in the opening phase, during the TCA dwell time.
Proceed as follows:
1 Press the hidden key of the transmitter, the code of which has already been stored in memory.
2 Within 5 seconds, press the already memorised transmitter key corresponding to the channel to be matched to the new transmitter.
The flashing light switches on.
3 Within 10 seconds, press the hidden key of the new transmitter.
4 Within 5 seconds, press the key of the new transmitter to be matched to the channel selected at item 2. The flashing light switches off.
5 The receiver stores the new transmitter code and exits from the programming mode immediately.
Some messages that are displayed in the event of malfunctions are shown hereunder:
Error, radiotransmitter self-adjustment
or
err
self-learning
Error, motor
Err1
Error, photocells
Err2
Error, encoder
Err5
Error, sensitive safety edge
Err7
Triggering of the amperometric sensor
amp
18
AUTOSET (AUTO)
PASSWORD (CODE)
ATTENTION:
(Menu Auto - See Stroke self learning)
EMERGENCY BATTERY
TRANSMITTER REMOTE LEARNING
ERROR MESAGES
If the error occurs during self-learning, check the STOP/PHOTO/PP/CLOSE in-
puts or whether frictions occur during the door leaf stoke.
If the error occurs during self-learning of the radio-transmitters, this means that
the memory of the receiver is no longer able to receive other transmitters or the
transmitter is not compatible.
Check connections to the motor
Check connections to photocells
Check connections to the encoder
Check connections and the operation of the sensitive safety edge
An obstacle or a point of friction has caused the triggering of the amperometric
sensor. Remove the obstacle or check the door stroke. Act on the PMO/PMC
parameter, if required.