The rapid closure is enabled or disabled. It can be activated only if TCA:ON
On: enabled rapid closure. With open gate, the photocell activation causes the
automatic closure after 3 s.
SCL
If the photocell is activated during the opening phase, the operation is completed
and closure starts after 3s
Off: disabled rapid closure.
The operating mode of "P.P. Push button" and of the transmitter are selected.
PP
On: Operation : OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
Forewarning flashing light enabled or disabled.
On: enabled forewarning flashing light. The flashing light is activated 3 s before the
PRE
starting of the motor.
Off: disabled forewarning flashing light.
The Service Man function is enabled or disabled.
(The OPCL logics is automatically enabled).
On: Service Man operation. The Step-by-Step input becomes OPEN input, the PED
input becomes CLOSE input.
HTR
If the OPEN and CLOSE keys are pressed at the same time, the system will STOP.
The OPEN/CLOSE push buttons should be kept pressed for the entire operating
time.
Off: Automatic operation.
During the TCA time, the blinker is enabled or disabled.
LTCA
On: Enables blinker.
Off: Disables blinker.
The code programmable transmitters is enabled or disabled.
On: Radio receiver enabled only for rolling-code transmitters.
CVAR
Off: Receiver enabled for rolling-code and programmable code transmitters (self-
learning and Dip Switch).
Soft start is enabled or disabled.
On: Starting is performed at reduced speed and then movement is restored to normal
SOFT
speed.
Off: Soft start is disabled.
PP input as OPEN and PED input as CLOSED are enabled or disabled.
OPCL
On: PP input is enabled as OPEN and PED input is enabled as CLOSED.
Off: PP and PED inputs are enabled with their function.
The checks on the photocell connected to PHO input are activated or deactivated.
Before carrying out the closing operation, the control unit checks that the photocell
contact has switched (this function is activated only with ESA:ON).In the negative,
tst1
the operation will not start.
On: check on photocells is activated
Off: check on photocells is deactivated
Checking on the photocell connected to PHC input is activated or deactivated.
Before carrying out the closing operation, the control unit checks that the photocell
contact has switched (this function is activated only with ESA:ON). In the negative,
tst2
the operation will not start.
On: checking on photocells is activated
Off: checking on photocells is deactivated
Select the opening direction of the motor (see Fig. 4 ):
On: Right side motor mount
minv
Off: Left side motor mount
If this logics is modified, this SELFTESTING will have to be repeated.
The ESA" energy savings function is activated or deactivated.
On: After completion of the opening or closing operations, the control unit switches
to the energy saving mode, while reducing current consumption to the minimum and
cutting off power from the transformed and the accessory outputs. Note: The ESA
function does not activate if:
ESA
- the battery recharge module is being recharged
- the AUX2 logics is on 0 and the gate leaf is open.
- during activation the service light if AUX2 is on 2.
Off: disabled energy savings. This is to be used should the accessory power supply
output is to be always activated, e.g. if keypads powered at 24VDC or other devices
that need to be always powered, are used.
16
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(ON)
(OFF)
(OFF)
(OFF)
(OFF)
(ON)