Hard Disk Expansion And Mirroring Setting - Sony HSR-X200 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Settings
When using the RS-232C or RS-485 interface, perform
the necessary settings with 2. RS-232C/RS-485 SET of
MAIN MENU 2.
For details on menu operations, see "Menu Operations" on
page 17(GB).
<RS-232C/RS-485 SET>
CONTROL
DATA SPEED
STATUS INFO
ALARM INFO
ADDRESS
CONTROL: Select RS-232C or RS-485.
DATA SPEED: Select the transmission speed from
among 2400/4800/9600/19200.
STATUS INFO: Set to ON when transmitting status
information of this unit.
ALARM INFO: Set to ON when transmitting alarm
information of this unit.
ADDRESS: Set the address (1 to 127) when using RS-
485.
For the RS-232C or RS-485 interface commands, see
"Commands" on page 67(GB).
: RS-232C
: 19200
: ON
: ON
: 000
Hard Disk Expansion and
Mirroring Setting
An optional HSBK-X201 hard disk drive can be added
for built-in hard disk expansion.
The added hard-disk drive will become usable after
initialization.
For mounting the HSBK-X201, ask your Sony dealer.
Initializing the hard disk for expansion
When you first supply power to the recorder after
hard-disk expansion, the HDD SET display
automatically appears. NEW is displayed on the line
for the added disk.
<HDD SET>
DISK 1 : 80GB
DISK 2 : 80GB NEW INITIALIZE c
PLEASE INITIALIZE THE NEW DISK
CAUTION : ALL RECORDING WILL BE ERASED!
MIRRORING
PLAYBACK DRIVE : DISK 1
CAUTION : RECORDING SPEED WILL BE
LIMITED BY MIRRORING!
NEXT c
Initialization of the disk on the highlighted line begins
once you turn the Shuttle dial
Activating the mirroring function
When the unit is equipped with two hard disks, the
mirroring function to record the same data on both of
the disks can be activated.
MIRRORING: Set to ON to activate the mirroring
function.
PLAYBACK DRIVE: Select the drive from which to
read the data for playback if data are recorded on
both drives with the mirroring function.
Note
In mirroring, when you set MIRRORING to ON, the
maximum recording cycle available will be limited to
0.05 sec (20 fields/sec, NTSC) / 0.06 sec (16.7 fields/
sec, PAL). Along with this, it includes a case for
recording time change. So, please always check
recording time available and the number of times for
alarm via "NORMAL REC MODE SET" and
"ALARM REC MODE SET" in the menu.
: OFF