DANGER:
Laser radiation. Avoid direct eye contact with light source.
WARNING:
Use of controls or adjustments or performance of
procedures other than those specified herein can result
in hazardous radiation exposure.
TO ADJUST THE LASER GUIDE
See Figure 37.
 Set miter and bevel angles to 0º.
 Use the work clamp or a C-clamp to secure a piece of
scrap wood.
 Plug the saw into the power source and make a slight
cut to score the wood.
 Release the switch trigger and allow the saw blade to
stop rotating before raising the blade.
 Raise the saw arm.
 Unplug the saw.
 Turn the laser switch on.
 Using the Phillips end of the supplied blade wrench, turn
the laser adjustment screw counterclockwise to move the
laser line left or clockwise to move the laser line right.
NOTE: When properly aligned, the laser should be on the
left edge of the kerf.