PRO LIFTS VMB ShowLift AED-SL18 Manual De Instrucciones página 11

Torre show electrónica
Tabla de contenido

Publicidad

Quick operation guide
and press UP
or DOWN
between one and the other. Then press
the central button to exit the menu and
save the choice.
1 DMX / MANUAL
< DMX >
CHANNEL
FUNCTION
1
Height
2
Speed
To change the DMX address press the
RIGHT
button to modify and use the
UP
and DOWN
address, then save the value by pressing
the central button "Enter".
DMX values between 1 to 512.
2 DMX ADRESS
2
CAUTION:
To change from DMX mode to MANUAL
mode the lift keeps the last position so it
will not move, but when changing from
MANUAL to DMX, the lift will move to the
DMX value of the console.
DMX SCALING
When setting the speed or height restric-
tions, there is the possibility to rescaling
the DMX values from 0 to 255.
This means that if the restrictions are set
in (for example) at a minimum height of
50 and a maximum height of 150, when
the rescaling is ACTIVE the minimum va-
lue of 50 will become 0, and the maximum
value of 150 will become 255.
PRO LIFTS S.L.
to toggle
1 DMX / MANUAL
< MANUAL >
EFFECT
0-255 (bottom-top)
0-255 (slow-fast)
buttons to select the
2 DMX ADRESS
< 230 >
Depósito legal y copyright 2018. Todos los derechos reservados.
ENGLISH
This can be activated in the following
screen pressing the RIGHT
then press the UP
to choose between active / inactive, and
then press ENTER key to select the cho-
sen option.
3 DMX SCALING
<ACTIVE / INACTIVE>
When the DMX scaling is ACTIVE, the
display will show a single "S" after the
mode.
In case the tower is out of the range set
in the height restrictions, the screen will
show two possible cases:
If the current position of the tower is un-
der the minimum height range, an "u" will
be displayed before the "P" of the posi-
tion, and the values will be negative:
SYS OK MANUAL S
uPOS: -050
If, on the other hand, the current position
of the lifter is over the maximum height
restriction previously set, an "o" will be
displayed before the "P" of the position,
and the values will exceed 255:
SYS OK MANUAL S
oPOS: 380
In these cases, the user can only move
the tower in manual mode to the position
within the set margins, for example, if the
tower is above the maximum, it will move
only downwards, and vice versa.
button,
and DOWN
keys
11