Operating Features ...........................................
Independently assign each station's cycle lengths, number of
cycles per day, and days between watering.
Cycle each station to water up to 28 times per day (14 times per
program).
No fuse needed: electronic short circuit detection warns of a
short, then continues to next station.
No battery needed: programs stored for up to 10 continuous
hours. With optional battery, programs saved for up to 7 months.
Adjust delay time between watering cycles, from 30 min. to
12 hrs., in one-hour steps.
With one touch, pause automatic watering, then restart.
Press the Rain button to stop automatic watering indefinitely.
Set days on which no watering will occur.
Manually run an entire program or a single station at any time.
At the touch of a button, make seasonal adjustments for wet or
dry spells.
Set up two completely different programs, A and B, to meet
diverse watering needs (drip and spray, for example). It's like
having two controllers.
Lock cover to resist tampering.
Connect a rain sensor directly to the controller, or manually
override the sensor simply by pressing a button.
Rely on proven superior surge protection.
Connect to a 24V master valve or pump relay.
Maximum run time: 3 hours, 59 minutes per station.
Specifications ....................................................
Primary input voltage: 120 VAC
Nominal, 60 Hz. Outdoor, (24
VAC @ 1A indoor).
Station output voltage: 24 VAC,
0.5A maximum.
Pump/master valve output
voltage: 24 VAC, 0.4A maximum.
Conduit size: Primary power
conduit size:
wiring conduit size: 1" (25 mm)
1
to 1
/
" (38 mm).
2
4
1
/
" (13 mm); field
2
Valves per station: Maximum 2
standard-draw solenoids or 6
Hunter low-current solenoids.
Optional battery: 9 volt
alkaline.
Field wiring size: 14 AWG
maximum.
Rain sensor: Interrupt type.
Surge protection: MOV type on
each station and primary power.