Beninca JM.3 Manual Del Usuario página 14

Ocultar thumbs Ver también para JM.3:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 21
Faston F1 (white) regulates the opening and closing speed
of the door and can be preset on three voltage positions:
JM.3:
• 20V: for sectional and balancing doors
• 28V: for sectional doors only
• 35V: for sectional doors only (8.9 m/1')
JM.4:
• 20V: for sectional and balancing doors
• 28V: for sectional doors only
• 35V: for sectional doors only (8.9 m/1')
Faston F2 (red) must not be moved from 20V position.
WARNING!: The adjustment of the door movement
speed affects the safety level of the automatic system.
Comply with regulations in force.
5. Accessories (optional)
JM.CB Emergency Battery Kit:
It permits the operation of the automatic system in the event
of power failure.
The kit is composed of: battery charge card, 2 batteries at
12V, fitting bracket, screws and cables.
The batteries must be installed on the upper part of the gear
motor basis, as per Fig.16.
To connect batteries, please refer to specific instructions.
Note: Once installed, the batteries protrude from the track
upper profile by approx. 10mm.
JM.PP Cord Manual Control:
It permits the control of the automatic system from indoor by
means of a cord, thus avoiding the installation of a keyboard.
The kit is composed of: micro-switch group, cord control with
knob, spring and cables (Fig.17)
For the installation, please refer to specific instructions.
Fig.19 shows the cord in working position.
6. Manual operation from outdoor
In sectional doors, the system can be released also from
outdoor by using item JM.SF (Fig.19).
A. Insert the metal cable in the slide, as indicated in Figure 19.
B. Fit the adjuster on the bracket and insert the sheath.
C. Fix the other end of the cable to the release device. The
figure shows an example of connection to the garage door
handle AU.MS.
N.B.: Any type of cord release device can be used under
the condition that the release stroke is of at least 15 mm.
If the device is able to keep the lever in the release position
(e.g. AU.MS) it would be easier to cut the hooking lever, as
shown in the detail of Fig. 19. In this way, by moving the han-
dle in the original position, the automatic operation is reset.
7. Assembling onto balancing doors
Overhead door with balanceweights (fig.20): these doors
need the special arm art. AU.C25.
In order to assemble it make sure that:
• the arm is fixed to the top edge of the door.
• the arm is levelled.
The civil liability policy, which covers possible injuries to peo-
ple or accidents caused by defects in construction, requires
to use original Benincà accessories.
14
CAUTION

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Jm.4Jm.3 esaJm.4 esa

Tabla de contenido