To avoid injury, do not touch the air inlet or aluminum fins of the unit.
Do not use the grips in the fan grills to avoid damage.
The unit is top heavy! Prevent the unit from falling due to improper inclination during handling.
The position of barycenter for different unit can be seen in the picture below.
540
234
707
5/7/9 kW (unit:mm)
5 IMPORTANT INFORMATION FOR THE REFRIGERANT
This product has the fluorinated gas, it is forbidden to release to air.
Refrigerant type: R32; Volume of GWP: 675.
GWP=Global Warming Potential
Model
5kW
7kW
9kW
12kW
14kW
16kW
CAUTION
1000mm
The hook and barycenter of
the unit should be on a line
in vertical direction to
prevent improper inclination
Make the rope go through
the lifting holes from both
the right and left sides in the
wooden collet
540
605
222.5
Factory charged refrigerant volume in the unit
Refrigerant/kg
2.00
2.00
2.00
2.80
2.80
2.80
97
605
641
12/14/16 kW (unit:mm)
Tonnes CO
equivalent
2
1.35
1.35
1.35
1.89
1.89
1.89