Test Run And Final Checks; Final Checks - mundoclima AEROTHERM MAM-V9 Serie Manual De Usuario E Instalacion

Monobloc
Ocultar thumbs Ver también para AEROTHERM MAM-V9 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

T1S
T_DRYPEAK
t_DRYUP
t_HIGHPEAK
When the cursor is on OPERATE FLOOR DRYING? Use
to scroll to YES and press OK. The page will be
displayed as follows:
12.3 FLOOR DRYING UP
Do you want to turn off the
floor drying up function?
NO
OK
CONFIRM
SCROLL
During floor drying, all the buttons except OK are invalid.
When the heat pump malfunctions, the floor drying mode
will turn off when the backup heater and additional
heating source is unavailable. If you want to turn off floor
drying up, please press OK. The following page will be
displayed:
13 AUTO RESTART
COOL/HEAT MODE
DHW MODE
SCROLL
Use
to scroll the cursor to YES and press OK. Floor
drying will turn off.
10.7.13 AUTO RESTART
About AUTO RESTART
The AUTO RESTART function is used to select whether
the unit reapplies the user interface settings at the time
when power returns after a power supply failure.
How to set the AUTO RESTART
Go to MENU> FOR SERVICEMAN>
AUTO RESTART
12.3 FLOOR DRYING UP
The unit will operate floor
drying on 09:00 16-12-2015.
OK
CONFIRM
t
t_DRYD
YES
YES NO
YES
NO
156
Use
,
,
,
to scroll and use OK to select YES or
NON to enable or disable the auto restart function. If the
auto restart function is enabled, when power returns after
a power supply failure, the AUTO RESTART function
reapplies the user interface settings at the time of the
power supply failure. If this function is disabled, when
power returns after a power supply failure, the unit won't
auto restart.
10.7.14 Description of terms
The terms related to this unit are shown in the table
below.
Parameter
llustration
Outlet water temperature of
T1
backup heater
Outlet water temperature of
T1B
additional heating source
T1S
Target outlet water temperature
Temperature of refrigerant at
outlet /inlet of plate heat
T2
exchanger when in heat
mode/cool mode
Temperature of refrigerant
at let outlet /inlet of plate
T2B
heat exchanger when in heat
mode/cool mode
Temperature of tube at
outlet/inlet of condenser
T3
when in cool/heat mode
T4
Ambient temperature
Temperature of domestic
T5
hot water
Th
Suction temperature
Tp
Discharge temperature
Inlet water temperature of plate
TW_in
heat exchanger
Outlet water temperature of
TW_out
plate heat exchanger
AHS
Additional heating source
IBH1
The first backup heater
IBH 2
The second backup heater
Backup heater in the domestic
TBH
hot water tank
Evaporate/condense pressure
Pe
in cool/heat mode
11 TEST RUN AND FINAL
CHECKS
The installer is obliged to verify correct operation of unit
after installation.

11.1 Final checks

Before
switching
on
the
recommendations:
unit,
read
following

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido