Immergas MINI Eolo X 24 3 E Manual De Instrucciones Y Advertencias página 263

Ocultar thumbs Ver también para MINI Eolo X 24 3 E:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 7
3.2 WIRING DIAGRAM.
3
Key:
B1 - Flow probe
B2 - Domestic hot water probe (optional)
B4 - External probe
CAR
- Comando Amico Remoto remote control
V2
Version 2 (optional)
DS1 - Display
E3 - Ignition and detection electrodes
E4 - Safety thermostat
F1 - Phase fuse
M1 - Boiler pump
M20 - Fan
M30 - Three-way valve (disconnected) (optional)
The boiler is designed for application of a room
thermostat (S20), an On/Off room chronother-
mostat, a program timer or a Comando Amico
Remoto remote control
(CAR
V2
to clamps 40 - 41 eliminating the jumper X40,
paying attention not to invert the polarity if the
CAR
is installed.
V2
Cylinder unit: the boiler is prepared for the ap-
plication of a storage tank unit, which must be
connected to clamps 36 and 37 of the bipolar
terminal board positioned under the sealed
chamber.
The connector X3 is present in the boiler but
must be connected only if the storage tank unit
is present.
The connector X8 is used for the connection
of the Virgilio Palmtop in the microprocessor
software updating operation.
3.3 TROUBLESHOOTING.
N.B.: Maintenance must be carried out by a
qualified technician (e.g. Immergas Technical
After-Sales Assistance Service).
R8 - Storage tank resistance
S2 - Selector switch functioning
S3 - Reset block keys
S4 - Domestic hot water flow switch
S5 - System pressure switch
S6 - Flue gas pressure switch
S20 - Room thermostat (optional)
S21 - Domestic hot water temperature
S22 - Domestic hot water temperature
S23 - Heating temperature increase key
S24 - Heating temperature reduce key
- Smell of gas. Caused by leakage from gas circuit
pipelines. Check sealing efficiency of gas intake
circuit.
). Connect
V2
- The fan works but ignition discharge does not
occur on the burner ramp. The fan may start
but the safety air pressure switch does not
switch the contact over. Make sure:
1) the intake/exhaust duct is not too long (over
allowed length).
2) the intake/exhaust duct is not partially
blocked (on the exhaust or intake side).
3) the diaphragm of the flue exhaust is adequate
for the length of the intake-exhaust duct.
4) that the sealed chamber is kept in good condi-
tions.
5) the fan power supply voltage is not less than
196 V.
- Irregular combustion (red or yellow flame).
This may be caused by: dirty burner, incorrect
combustion parameters, intake - exhaust ter-
minal not correctly installed. Clean the above
components and ensure correct installation of
the terminal.
1
2
increase key
reduce key
T1 - Low voltage feeder
T2 - Switch-on transformer
U1 - Rectifier inside the gas valve
connector (Only available on
Honeywell gas valves)
X40 - Room thermostat jumper
Y1 - Gas valve
Y2 - Gas valve modulator
1 - User interface
2 - N.B.: The user interface is on
the welding side of the boiler
board
3 - 230 Vac 50Hz power supply
4 - Blue
5 - Brown
6 - Yellow/Green
7 - Black
8 - (DHW)
9 - (central heating)
10 - Grey
11 - White
12 - Red
13 - Green
14 - Storage tank unit (optional)
- Frequent interventions of the over heating
safety thermostat. It can depend on reduced
water pressure in the boiler, little circulation
in the heating system, the blocked pump or
an anomaly of the boiler P.C.B. Check on the
manometer that the system pressure is within
established limits. Check that radiator valves
are not all closed.
- Presence of air in the system. Check opening of
the hood of the special air vent valve (Fig. 1-33).
Make sure the system pressure and expansion
vessel pre-charge values are within the set
limits; the pre-charge value for the expansion
vessel must be 1.0 bar, and system pressure
between 1 and 1.2 bar.
- Ignition block see par. 2.5 and 1.4 (electric
connection).
ES
PT
GR
14
PL
TR
CZ
SI
HU
RU
RO
IE
SK
Fig. 3-2
UA
261

Publicidad

Tabla de contenido
loading

Tabla de contenido