Descargar Imprimir esta página

Dornbracht 35 260 970 90 Instrucciones De Montaje página 40

Publicidad

Minimum fl ow pressure =
Maximum fl ow pressure =
Maximum fl ow pressure difference between
hot and cold water =
Recommended fl ow pressure =
Permitted operating temperatures
Hot water temperature range =
Cold water temperature range =
Electrical system
Rain panel ceiling installation housing
Electrical connections (input voltage) in the
sub-distributor =
Electrical connections (input voltage) in the rain panel ceiling
installation housing =
Input frequency =
Maximum power consumption =
Output voltage =
Output voltage =
Power consumption (Sleep mode)
Power consumption (operation) =
Degree of protection =
Potential equalization =
Operating elements = display switch and control knobs
Input voltage =
Degree of protection =
Hole diameter of FM box =
Preassembly kit for eVALVE (hand shower set)
Input voltage =
Degree of protection =
Potential equalization =
Fragrance module
Input voltage =
Input frequency =
Maximum power consumption (for 3 modules) =
General
Weight of rain panel =
Ambient temperatures
rain panel max.
rain panel min.
operating elements max.
operating elements min.
storage max.
storage min.
fragrance module max.
fragrance module min.
Store in a clean and dry place!
To be provided by the customer:
Minimum space requirement for components in
sub-distributor =
Minimum space requirement for each fragrance
module (3x) =
Protective circuit breaker, 2-pin,
Circuit breaker,
- 3 contact breakers (16A, 1S, 230 V AC)
Circuit breaker for sub-distributor (6 A)
Conduit (for power supply) from the sub-distributor to the rain
panel ceiling installation housing =
Conduit (for Ethernet cable) from the sub-distributor to the rain
panel ceiling installation housing =
40
36 psi
Conduit (for fragrance hoses) from the rain panel ceiling installation
58 psi
housing to the fragrance module =
2 conduits (for signal line or power supply) from the sub-distributor
115 psi
to the fragrance module =
44 psi
Conduit (for potential equalization cable) from the sub-distributor
to the rain panel ceiling installation housing / preassembly kit for
eVALVE (hand shower set) =
122-140 °F
Potential equalization cable for the rain panel ceiling
41-68 °F
installation housing / preassembly kit for eVALVE
(hand shower set) =
Label
Self-declaration:
100-240 V AC
12 V DC
Användningsvillkor
SE
50-60 Hz
Sanitär
180 W
12 V DC
Flödestryck
3 x 5 A
Min. flödestryck
< 5 W
Max. flödestryck
160 W
Max. flödestrycksdifferens mellan varm- och kallvatten
IP 54
Rekommenderat flödestryck
4 mm²
Tillåtna driftstemperaturer
Varmvatten-temperaturområde
12 V DC
Kallvatten-temperaturområde
IP X4
2 ¼"
Elektrisk installation
Kåpa för montering av duschpanel
Elanslutning (ingångsspänning) i undercentral
12 V DC
Elanslutning (ingångsspänning) i kåpa för montering av
IP 66
duschpanel
4 mm²
Ingångsfrekvens
Max. effektförbrukning
Utgångsspänning
230 V AC
Utgångsström
50-60 Hz
Effektförbrukning (sleep mode)
30.6 W
Effektförbrukning (drift)
Kapslingsklass
Potentialutjämning
132 lbs
Reglage displaybrytare och vridreglage
Ingångsspänning
131 °F
Kapslingsklass
41 °F
Borrhålsdiameter inbyggd dosa
95 °F
41 °F
Inbyggnadssats eVALVE (slangduschset)
95 °F
Ingångsspänning
41 °F
Kapslingsklass
86 °F
Potentialutjämning
41 °F
Doftmodul
Ingångsspänning
Ingångsfrekvens
Max. effektförbrukning (för 3 moduler)
20" x 20"
Allmänt
Vikt duschpanel
12" x 12" x 5"
30 mA, type A
Omgivningstemperatur
6 A, type B
Max. regnpanel
Min. regnpanel
Max. reglage
Min. reglage
Ø 32 mm, max. 39 ft.
Max. förvaring
Min. förvaring
Ø 32 mm, max. 39 ft.
Max. doftmodul
Ø 32 mm, max. 39 ft.
Ø 32 mm, max. 3ft. 4".
Ø 20 mm
4 mm² each
CE
2,5 bar
4,0 bar
1,0 bar
3,0 bar
50-60 °C
5-20 °C
100-240 V AC
12 V DC
50-60 Hz
180 W
12 V DC
3 x 5 A
< 5 W
160 W
IP 54
4 mm²
12 V DC
IP X4
56 mm
12 V DC
IP 66
4 mm²
230 V AC
50-60 Hz
30,6 W
60 kg
55 °C
5 °C
35 °C
5 °C
35 °C
5 °C
30 °C

Publicidad

loading