Carbon Brushes; Recommended Accessories - skilsaw SPT99 Instrucciones De Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

WORM DRIVE GEAR LUBRICATION
Your Skilsaw tool has been properly lubricated
and is ready to use. However it is recommended
that the gears be re-lubricated only with Skilsaw
lubricant: No. 80111 (8 oz. tube).
Always check the oil level before using the saw. At
a minimum, the oil should be changed once a year
under heavy use, or after approximately 60 hours
of use.
To check and add oil: Remove the plug from the
power source. Move the blade to its lowest posi-
tion. Place the saw on a flat, stable surface with
the table facing upward (see Fig. 68 ). Remove oil
plug using the 1/2" wrench. Check to ensure that
the oil is not below the level of the threads.
To replace the oil: Place an oil catchment under
the spigot and gently tip the table saw up so that
the oil spigot is pointing down into the oil catch-
ment and the handle is facing upwards. Allow the
oil to drain out of the gear housing. Place the
table saw back level on its feet. Using an oil refill
pipette, refill the oil until it reaches the bottom
threads of the housing. Do not over fill. Replace
the oil plug when finished. Clean off any oil on
the exterior surfaces of the tool prior to use.
NOTE: When checking the oil, if it is dirty or thick,
replace the oil plug and run the saw for one minute
to warm the oil. Then remove oil plug and turn saw
upside down, to remove all oil. Add fresh Skilsaw
lubricant (No. 80111). With a new saw, change
the oil after the first ten hours of use.

CARBON BRUSHES

The brushes and commutator in your tool have
been engineered for many hours of dependable
service. To maintain peak efficiency of the motor,
it is recommended to examine the brushes every
two to six months. The brushes should be free
from dust and dirt. Brushes should be replaced
when they have worn down to 3/16" in length.
The brushes should slide freely in and out of the
holders without sticking.
ITEM
ZERO CLEARANCE
INSERT
DADO INSERT 13/16
REAR OUTFEED
DADO INSERT 1/2
Maintaining Your Table Saw

Recommended Accessories

CATALOG NO.
SPT00C
SPT00A
SPT00B
SPTA70WT-DD
Top Brush
Bottom Brush
To check brushes:
1. Disconnect plug from power source.
2. Move the blade to its lowest position (see Fig.
68).
3. To check top brush: Place the saw on a flat,
stable surface with the table facing upward.
To check bottom brush: Place the saw on a
flat, stable surface with the Cord Wrap end fac-
ing upwards.
4. Loosen the brush cap on the motor housing by
rotating it a 1/4 turn using a either a short
screwdriver or a quarter, then finish removing
the brush by hand. Note which way the brush
faces, so that it can be returned to its original
position.
5. Clean the brush holder opening with com-
pressed air or a clean cloth.
6. Replace the brush and cap.
your tool should be used.
structions that accompany accessories. Use
of improper accessories may cause hazards.
-51-
Oil Plug
Only genuine Skil replacement
brushes specially designed for
Use only recommended
accessories. Follow in-
FIG. 68

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido