Festool TKS 80 EBS Manual De Instrucciones página 33

Ocultar thumbs Ver también para TKS 80 EBS:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 60
The green
The bench-mounted
LED [2-4] lights
circular saw is ready
up constantly.
to use and is in stand­
by mode.
The red
LED [2-5] is not
lit.
The green
Restart protection
LED [2-4] flash­
When activating by­
es rapidly.
pass mode, the yel­
low SawStop switch
(alternating)
was released too ear­
The red
ly.
LED [2-5] flash­
es rapidly.
fault, press the red
STOP button.
The green
Contact with the saw
LED [2-4] lights
blade in standby.
up constantly.
contact trigger and
The red
wait approx. 5 sec­
LED [2-5] flash­
onds until the fault is
es rapidly.
rectified.
The green
Cartridge locking de­
LED [2-4] is not
vice fault.
lit.
bench-mounted cir­
The red
cular saw and check
LED [2-5] flash­
the cartridge locking
es slowly.
device.
The green
Saw blade missing or
LED [2-4] flash­
too small.
es slowly.
bench-mounted cir­
The red
cular saw and insert a
LED [2-5] lights
suitable saw blade
up constantly.
(see section
The green
Replace the car­
LED [2-4] is not
tridge.
lit.
bench-mounted cir­
The red
cular saw. If the fault
LED [2-5] lights
is still not rectified,
up constantly.
insert a new car­
tridge.
To rectify the
Remove the
Switch off the
Switch off the
3
).
Switch off the
LED status during operation
The green
LED [2-4] flash­
es rapidly.
The red
LED [2-5] is not
lit.
The green
LED [2-4] flash­
es slowly.
The red
LED [2-5] is not
lit.
The green
LED [2-4] flash­
es slowly.
The red
LED [2-5] flash­
es rapidly.
LED status in standby or during operation
The green
LED [2-4] is not
lit.
The red
LED [2-5] flash­
es rapidly.
The green
LED [2-4] flash­
es rapidly.
The red
LED [2-5] lights
up constantly.
8.2
Activating the SawStop technology
The SawStop technology is activated upon
delivery and after each time the saw is put
back into operation.
English
The saw blade comes
to a stop.
The SawStop
technology is active
and is triggered upon
contact.
Activated bypass
mode.
Contact with the saw
blade while bypass
mode is activated
The fault is rectified if
the saw blade comes
to a stop.
Workpiece too damp.
Switch off the
bench-mounted cir­
cular saw and dry the
workpiece or contin­
ue sawing in bypass
mode.
The saw blade comes
to a stop during saw­
ing.
Switch the
bench-mounted cir­
cular saw off and on
and saw the work­
piece more slowly.
Or:
The bench-mounted
circular saw is opera­
tional and the yellow
SawStop switch has
been pressed.
Switch the
bench-mounted cir­
cular saw off and on.
33

Publicidad

Tabla de contenido
loading

Tabla de contenido