Descargar Imprimir esta página

Prior To Commissioning - Taski swingo 455B Manual Tecnico

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 79
Attention:
Before decommissioning the machine for
a longer period, the batteries must under-
go a complete charging cycle. After com-
pletion, the charger is disconnected from
the machine and/or mains. Batteries grad-
ually discharge. Depending on the type of
battery, they must be recharged after 3-6
months. Before recommissioning, the bat-
teries should undergo another complete
charging cycle.
Charging procedure with external charger
• Connect the external battery charger with the battery iso-
lating plug of the machine.
Attention:
Make sure that the plug is inserted up to
the stop in order to ensure a good electri-
cal contact.
Notice:
All machine functions are deactivated
during charging.
Charging procedure with (optional) on-board charger
Attention:
The machine must be switched off (main
switch) and the battery disconnection plug
must be disconnected.
• Take the power cord and connect it with a socket (with slow
fuse).
After charging
Attention:
Switch off the charger before disconnect-
ing the batteries (only for external char-
gers).
Disconnecting the charger while it is still
switched on may result in an explosion in
the battery compartment.
• Stow away the power cord for (optional) on-board chargers
in the provided compartment.
• Store the charging cable in a dry place where it is protected
against damage.
Attention:
Charging cables transfer high currents. Do
not use the charger if there are any signs
of damage to the plug, cable or device
connection.
Maintenance and care of open (wet-cell) batteries
Notice:
The care for maintenance-free batteries is
limited to the compliance with the correct
charging processes and correct adjust-
ment of the charging curve.
Open battery compartment for maintenance
• The machine must be switched off.
Caution:
Before opening the battery compartment
make sure that both tank areas are empty.
• At the bottom left and right on the
front side of the machine you will find
the battery compartment release.
• Undo the screws.
• Carefully tip the tank backwards.
Now the battery can be maintained
according to the manufacturer's noti
fication.
Caution:
After maintenance, carefully bring the tank
back to its initial position and screw in the
screw.

Prior to commissioning

Brush installation
Before inserting, please check:
• that the brush does not fall below the red marking (bristles)
or 1cm of bristle length.
• the pad for wear and cleanliness before use.
Attention:
Do not use brushes which have reached
their wear limit. The wear limit is indicated
by the length of the red bristle. Do not use
worn or contaminated pads. Use original
TASKI brushes only. Failure to observe
these instructions may result in inade-
quate cleaning results or even floor dam-
age.
• Position the tools under the tool unit.
• Switch the machine on.
• To do this, press the main switch but-
ton (ON/OFF) for 3 seconds.
The display lights up briefly.
• Unlock the foot pedal and lower the
tool slowly.
• Briefly press the operating lever.
In this way the tool is centered and engaged.
EN
-
67

Publicidad

loading

Este manual también es adecuado para:

Swingo 455b