14. Fault correction

Fault
Water does not flow
at all
Water flows
continuously
Duration too short or
too long
Water flow too weak
Water flow too large
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform the AQUA service department.

15. Replacement parts

Designation
1 Activation valve . . . . . . . . . . . . . . . . . 82-100-10.964
2 Cover plate . . . . . . . . . . . . . . . . . . . . . 82-100-10.970
3 Frame with profile seal . . . . . . . . . . . 82-100-10.890
4 WC flush valve . . . . . . . . . . . . . . . . . . 82-100-10.760
4a Upper section . . . . . . . . . . . . . . . . . . 2600 24 30
5 Complete outlet connection . . . . . . . 82-100-10.644
6 Remote activation hose
Specify length in meters . . . . . . . 82-039-10.036
Replacement parts set for DN 20 consisting of:
Rubber parts
Spring
Seals . . . . . . . . . . . . . . . . . . . . . . 82-500-01.003
Cause
– Stop valve or flow volume regulator
closed.
– Upper section faulty
– Activation valve faulty
– Upper section faulty
– Activation valve faulty
– Flush volume adjustment incorrect
– Upper section faulty
– Stop valve or flow volume regulator
not fully opened.
– Supply pressure too low
– Flush volume adjustment incorrect
– Flush volume adjustment incorrect
Order No.
Remedy
➯ Open it
➯ Replace it
➯ Replace it
➯ Replace it
➯ Replace it
➯ Adjust it
➯ Replace it
➯ Open it
➯ Check it
➯ Adjust it
➯ Adjust it