15. Fault correction
Fault
Water does not flow
Water flows
continuously
Water flow too weak
Flow time too short or
too long
Water is too hot
Water is too cold
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform our service department!!
8
Cause
– Water flow regulator closed
– Functional part faulty
– Functional part faulty
– Valve seat dirty
– Aerator calcified
– Supply pressure too low
– Grit filter/return-flow inhibitor is
contaminated
– Water flow volume regulator not fully
opened
– Incorrect setting
– Mesh washer contaminated
– Aerator calcified
– Functional part defective
– Temperature limit is incorrectly set or
not set at all
– Cold water is turned off
– Return flow inhibitor in the cold
water connection is faulty
– Return flow inhibitor in the cold
water connection is faulty
– Hot water is turned off
Remedy
➯ Restore
➯ Replace it
➯ Replace it
➯ Clean it
➯ Clean it
➯ Check it
➯ Clean it
➯ Open it
➯ Adjust it
➯ Clean it
➯ Clean it
➯ Replace it
➯ Adjust it
➯ Open it
➯ Replace it
➯ Replace it
➯ Open it