ENGLISH
FUSE CHECK/REPLACEMENT
1.
Disconnect the battery connector (12).
2.
Move aside the recovery water drain hose (16).
3.
Remove the battery charger cable (I, Fig. 10) from the holder (J).
4.
Remove the screws (A) and carefully move aside the panel (B) by disengaging the grommet (K) from its housing on the panel (B).
5.
Check/replace the following fuses:
C)
F1 fuse, deck: (40 A)
D)
F2 fuse, vacuum system: (30 A)
E)
F3 fuse, drive system: (30 A)
F)
F4 fuse, signal circuits: (3 A)
G)
F5 fuse, brush/pad-holder release: (20 A)
H)
F6 fuse, pump: (3 A)
6.
Perform steps 1 to 4 in the reverse order.
BRUSH/PAD-HOLDER/CYLINDRICAL BRUSH DECK DISASSEMBLY/ASSEMBLY
The machine can be equipped with either the brush/pad-holder deck (18a and 18b) or the cylindrical brush deck (18c).
NOTE
When the deck is installed/removed, it may be necessary to change the squeegee too, because they must have the
same width. For correct matching of deck and squeegee, see the Squeegee Installation paragraph.
Disassembly
1.
Drive the machine on a level fl oor.
2.
Remove the brushes/pad-holders according to the procedure shown in the relevant paragraph. Do not remove the cylindrical
brushes.
3.
Lower the brush/pad-holder deck by pressing the pedal (11).
4.
If equipped, remove the cotter pins (B, Fig. 11) and the gas spring (A).
5.
Disconnect the brush/pad-holder motor electrical connection (D).
6.
Disconnect the solution hose (E) from the solenoid valve (F).
7.
Remove the screws (C), then remove the brush/pad-holder deck (F).
26
INSTRUCTIONS FOR USE
A
F G H
A
9096910000(2)2010-03
A
B
D
E
A
J
K
I
Figure 10
Adfi nity™ 20D - X20D - X20C - X24D
C
S311324