9. OPERATION
1. "8.8.8.8" Plug mains power cord from the faze
machine into appropriate power supply socket;
2. "u.X.X" Primary power on;
3. 1 seconds after, show the current software
version;
4. "HEAT" 2 seconds after, switches to working
status: heating up;
5. Wait about 75 seconds for heating element to
heat up;
6. "idLE" When heating completed, displays the
previous picture shows stand by status;
7. After the heating up is complete, Please do
follow the required operating modes;
Manual Continuous Fogging
Operatio
1. "idLE" When heating completed, displays the
previous picture shows stand by status;
2. Under this status, press "ENTER" to start fog-
ging;
3. Under Fogging status to adjust Puff Volume and
Fan;
4. "P.xxx" Press "Up" or "Down" to adjust Puff
Volume (5–100%);
5. Press MENU to switch Puff volume and Fan;
6. "F.xxx" Press"Up"or"Down"to adjust Fan (5–
100%);
7. Under fogging status, press " ENTER" to stop
fogging;
8. "cln_" Please note the machine design of ma-
chine stops working after a delay of 30 seconds,
automatically clear the tubing of the remaining
liquid;
9. "idLE" After cleaning, back to stand by status.
Under "idLE" or "cLn_s" tatus, still can operate the
machine, press MENU button to check and set numbers.
Timing Fogging Operation
1. "idLE" When heating completed, displays the
previous picture shows stand by status;
2. Press MENU to switch to built-in timer ON/
OFF;
3. "t.oFF" or "t. ON" Press "Up" or "Down" to
switch timer ON/OFF
4. Under built-in Timer ON, Press MENU to switch
Duration and Interval;
5. "d.xxx" Press "Up" or "Down" to adjust time
value of duration (3s – 250s);
6. "i.xxx" Press "Up" or "Down" to adjust time
value of interval (5s – 250s);
7. Press "ENTER" to start timing fogging;
8. Press again "ENTER" to stop Timing fogging;
9. "cLn_" Please note the machine design of
machine stops working after a delay of 30
seconds, automatically clear the tubing of the
remaining liquid
10. "idLE" After cleaning, back to stand by status.
Under "idLE" or "cLn." status, still can operate
the machine, press MENU button to check and set
numbers.
Other Operation Tips
Under "idLE" or "cLn_." press MENU button to
check and set numbers:
1. "t.oFF" / "t. on" Built-in timer On/Off,
2. "d.xxx" Built-in timer, single fogging duration
3s-250s
3. "i.xxx" Built-in timer, Interval fogging time
5s-250s
4. "A.xxx" DMX address setting 1-512 (press UP or
DOWN button to set)
For item 1, 2, 3: Press UP of Down to set numbers, 4