13. POWER CONNECTED, FOG BLASTS NOT SMOOTH
Should there be any low fog emitted, running noisi-
ly or hindered fogging, pull out the plug immediate-
ly. Check if string enough fluid, if the pipe connect-
ed to the tank is clean, if there's air inside the pipe,
if the liquid flows, if not, plug-in again; still persists
abnormal running, and If causation is unclear, stop
running to avoid any damage, shut down to cool
it, and bring unit to your local agent or appointed
service place for inspection, prohibit any dismantle-
ment by yourself.
14. OTHER ABNORMAL SITUATIONS
"Erro" Flashing and showing this status, means
heater is too hot or thermos sensor is cut.
"noHt" Flashing and showing this status, means
unable heating.
"noFL" Flashing and showing this status, means
fluid runs out or pumping no fluid. At this mo-
ment, speed of the fan will reduce to minimum,
and pump will stop working.
15. MAINTENANCE
Before doing maintenance, please make sure that
the power is cut, the power cord is unplugged, and
the machine itself has cooled down. The mainte-
nance must be done by qualified person. Before
doing maintenance, please make sure that the
power is cut, the power cord is unplugged, and the
machine itself has cooled down.
P. 14
Neo Steam F700 - English version
The maintenance must be done by qualified
person.
The liquid is not allowed to get dirty. Be sure
to always clean or replace the caps on the
liquid vessel and tight the cover of the faze
machine liquid tank immediately after filling.
Prolonged use, sponge inside the vent may

Publicidad