3.0 Safety

NB! To guarantee optimal performance and safety, Jøtul
stoves must be fi tted by a qualifi ed installer.
Any modifi cations to the product by the distributor, installer or
consumer may result in the product and safety features not
functioning as intended. The same applies to the installation of
accessories or optional extras not supplied by Jøtul. This may
also be the case if parts that are essential to the functioning and
safety of the fi replace have been disassembled or removed.
In all these cases, the manufacturer is not responsible or liable
for the product and the right to make a complaint becomes null
and void.
The Clean Air Act
"The Clean Air Act 1993 and Smoke Control Areas"
Under the Clean Air Act local authorities may declare the
whole or part of the district of the authority to be a smoke
control area. It is an offence to emit smoke from a chimney of
a building, from a furnace or from any fi xed boiler if located in a
designated smoke control area. It is also an offence to acquire
an "unauthorised fuel" for use within a smoke control area
unless it is used in an "exempt" appliance ("exempted" from
the controls which generally apply in the smoke control area).
In England appliances are exempted by publication on a list
by the Secretary of State in accordance with changes made to
sections 20 and 21 of the Clean Air Act 1993 by section 15 of
the Deregulation Act 2015. Similarly in Scotland appliances are
exempted by publication on a list by Scottish Ministers under
section 50 of the Regulatory Reform (Scotland) Act 2014.
In Northern Ireland appliances are exempted by publication
on a list by the Department of Agriculture, Environment and
Rural Affairs under Section 16 of the Environmental Better
regulation Act (Northern Ireland) 2016.
In Wales appliances are exempted by regulations made by
Welsh Ministers.
Further information on the requirements of the Clean Air Act
can be found here: https://www.gov.uk/smoke-control-area-
rules
Your local authority is responsible for implementing the Clean
Air Act 1993 including designation and supervision of smoke
control areas and you can contact them for details of Clean Air
Act requirements.
The Jøtul I 620 F, Jøtul I 620 FR, Jøtul I 620 FL and Jøtul I 620
FRL have been recommended as suitable for use in smoke
control areas when burning wood logs.

3.1 Fire Prevention Measures

There is a certain element of danger every time you use
your fi replace. The following instructions must therefore be
followed:
The minimum safety distances when installing and using
the fi replace are given in fi g. 1a and fi g. 1b.
Ensure that furniture and other fl ammable materials are
not too close to the fi replace. Flammable materials should
not be placed within 1000 mm of the fi replace.
Allow the fi re to burn out. Never extinguish the fl ames with
water.
The fi replace becomes hot when lit and may cause burns
if touched.
Only remove ash when the fi replace is cold. Ash can
contain hot embers and should therefore be placed in a
non-fl ammable container.
Ash should be placed outdoors or be emptied in a place
where it will not present a potential fi re hazard.
In case of chimney fi re:
Close all hatches and vents.
Keep the fi rebox door closed.
Check the loft and cellar for smoke.
Call the fi re service.
Before use after a fi re an expert must check the fi replace and
the chimney in order to ensure that it is fully functional.
3.2 Floor
Foundations
Ensure that the fl oor is strong enough for the fi replace. See
«2.0 Technical data» for weights.
Combustible fl oor protection
If the fi replace is to be mounted on a combustible fl oor, cover
the fl oor under and in front of the fi replace with a plate of
metal or other non- combustible material. The recommended
minimum thickness is 0,9 mm. The minimum distance between
the fl oor and the frame can not be less than 428mm (see fi g.
1f).
It is recommended that fl ooring which is not fastened to the
foundations – so-called fl oating fl ooring – is removed during
installation.
Jøtul recommends that any fl ooring made of combustible
material, such as linoleum, carpets, etc. should be removed
from under the fl oor plate.
The plate must be in accordance with national laws and
regulations.
Contact your local building authority regarding restrictions and
installation requirements.
Requirements for protection of infl ammable fl oors
in front of the fi replace
The fl oor in front of the fi replace must be protected by a sheet
of metal or other non-infl ammable material. The recommended
minimum thickness is 0.9 mm. The fl oor plate must comply
with national laws and regulations. Distance between fl oor and
frame must be a minimum of 428mm (see fi g. 1f)
Contact your local building authorities regarding restrictions
and installation requirements.
3.3 Wall
Distance to combustible wall protected by
insulation (fi g. 1)
The Jøtul I 620 Series can be installed inside an open
structure/surround, provided that the distance from the wall
(both combustible and non-combustible) is at least 700 mm on
the sides with glass, and at least 362 mm on the sides without
glass. These distances must be observed because of the heat
ENGLISH
39