3.0 Safety precautions

3.1 Fire preventive measures
• Ensure that furniture and other combustible materials do not
get too close to the fireplace.
• Never put out the fire with water.
• Ash should be disposed of out of doors or be emptied into a
place where it cannot cause a fire hazard. Any stove should
have a storage container made of incombustible material
with a lid for soot and ashes.
Soot and ashes must be stored in such a container for at
least one week in order to be certain that the last ember has
been extinguished. Then the container can be emptied, in the
dustbin, if desired.
If the container needs to be emptied before this, add plenty
of water to the container and stir.
• You may want to keep the ash. It makes for excellent fertilizer,
for roses, among other things.
3.2 Supply of air
Warning! Please ensure that there is adequate air supply from the
outdoors to the room in which the fireplace is to be installed.
Ensure that air vents in the room where the fireplace is located
are not blocked.
An inadequate air supply could cause smoke gas to escape into
the room. This is very dangerous! Symptoms of this include smoky
smell, drowsiness, nausea and feeling ill.
Avoid using mechanical fan vents in a room with a fireplace.
This may cause negative pressure and draw poisonous gasses
into the room.
26
All manuals and user guides at all-guides.com
3.3 Required measurements and distances
Necessary air openings in the surround: (Forced air)
Base:
Hood:
front.
Distance from the stove to the insulation on the back panel.
See fig. 1 and 2:
Minimum 50 mm.
Requirements for insulation
80 mm rock wool 120 kg/m
aluminium.
Distance from warm air opening in the hood's sides to the
ceiling/sides:
Min. 500 mm to ceiling of combustible material.
Min. 750 mm to wall of combustible material.
Distance from warm air opening in the hood's top to the ceiling/
sides:
Min. 600mm to ceiling of combustible material.
Min. 750 mm to wall of combustible material.
Requirement for protection of combustible floor in front of
stove:
The front plate must be in accordance with national laws and
regulations.
See fig. 1
Requirement to the distance from the insert's base to floor of
combustible material (see fig. 1 and 2):
Min 368 mm
Furnishing distance:
Min. 1300 mm.
Requirement for chimney:
Minimum cross section:
314 cm
491 cm
Minimum 750 cm
free opening.
2
Minimum 1,000 cm
free opening in the hood's sides/
2
foliated on one side with
3
for flue pipe Ø200 mm -
2
for flue pipe Ø250 mm.