Nussbaum POWER LIFT HF 3S 3000 Instrucciones De Servicio página 90

Ocultar thumbs Ver también para POWER LIFT HF 3S 3000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Time frame
Position
Type of
maintenance
12
1
11
2
10
1 x / 12
9
3
4
8
5
7
6
12
1
11
2
10
1 x / 12
9
3
4
8
5
7
6
12
1
11
2
10
1 x / 12
9
3
4
8
5
7
6
90
Check electrical components for function and condition.
• Plug.
• Operating lever with button switch.
• During assembly and maintenance always check the condition of
electrical lines. All cables and lines must be secured so they cannot
be crushed, kinked or contact any moving assembly.
Optional energy set:
• Electrical socket
• Pneumatic connection
Check for condition and function.
Check the paint:
• Check the powder coating and improve if required.
Damage by external influences is to be treated immediately after
detection. If these points are not treated, infiltration of deposits of all
kinds can cause wide-ranging and permanent damage.
These points are to be lightly sanded (120 grit), cleaned and de-
greased. Afterwards, rework with a suitable touch up paint (note the
RAL No.).
• Check galvanised surfaces, touch up as needed.
White rust is fostered by permanent humidity, poor ventilation. The
affected areas can be treated by using a sanding cloth (A 280 grit).
If required, the parts are to be treated with a suitable, resistant mate-
rial (paint etc.). Check the RAL colour selection.
• Rust is brought out by mechanical damage, wear, aggressive de-
posits (de-icing salt, leaking operating fluids) cleaning that is not
done or incomplete.
The affected areas can be treated by using a sanding cloth (A 280
grit). If required, post-treat the areas with a resistant material (paint
etc.).
OPI-POWER LIFT HF 3S 3000-4000 - HYMAX HF 3S 3000-4000 -V1.1-DE-EN-FR-ES-IT
Maintenance plan

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Power lift hf 3s 3500Power lift hf 3s 4000Hymax hf 3s 3000Hymax hf 3s 3500Hymax hf 3s 4000

Tabla de contenido