Balluff BTL7 Serie Manual De Instrucciones página 47

Ocultar thumbs Ver también para BTL7 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

BTL7-A/C/E/G5 _ _ -M _ _ _ _ -H/W(8)-S32/S115/_ _ _
Magnetostrictive Linear Position Sensor – Rod Style
9
Resetting all values (reset)
NOTICE!
Interference in function
Resetting the values while the system is running may
result in malfunctions.
► Stop the system before performing the reset.
The reset function can be used to restore all the settings
to the factory settings. For a reset the magnet may also be
located outside the measuring range.
Activate reset
► Simultaneously activate
a
Reset
► Simultaneously activate
a
After activation:
⇒ All values are reset.
⇒ Current position value is displayed.
⇒ Reset is deactivated.
Abort reset
Resetting can be aborted without any changes
being saved after the Activate reset step.
► Briefly activate
a
and
b
⇒ Current position value is displayed.
www.balluff.com
and
b
for at least 4 s.
and
for at least 4 s.
b
simultaneously (< 1 s).
a
b
> 4 s
a
b
> 4 s
a
b
< 1 s
Displayed values (example)
At 0...10 V
At 4...20 mA
5.39 V
9.15 mA
10.50 V
3.60 mA
0.00 V
4.00 mA
9.89 V
19.13 mA
english
19

Publicidad

Tabla de contenido
loading

Tabla de contenido