ALARM PROPERTY TABLE

CODE
A01
G
G
A02
G
G
G
G
A03
G
G
A04
G
G
A05
G
G
A06
G
G
A07
G
G
A08
G
A09
A10
G
G
G
A11
G
G
A12
G
G
G
G
A13
G
G
A14
G
G
A15
G
G
A16
G
G
A17
G
G
A18
G
A19
UA1
UA2
UA3
UA4
UA5
UA6
UA7
UA8
A20
A21
A22

COMMANDS MENU

– The commands menu allows executing some occasional operations, such as measurement reset, counter clearing, alarm reset, etc.
– If the Advanced level password has been entered, then the commands menu allows executing the automatic operations useful for the device configuration.
– The following table lists the functions available in the commands menu, divided by the access level required.
CODE
COMMAND
C01
Reset partial energy meter
C02
Reset CNTx counter
C03
Reset LIMx status
C04
Reset max temperature
C05
Reset max overload
C06
Reset step hour count
C07
Reset step switching counters
C08
Step power restore
C09
Reset total energy meter
C10
TEST mode activation
C11
Event log reset
C12
Setup to default
C13
Backup setup
C14
Restore setup
C15
Reset weekly TPF
C16
Reset maintenance interval 1 elapsed
C17
Reset maintenance interval 2 elapsed
C18
Reset maintenance interval 3 elapsed
– Once the required command has been selected, press
The device will prompt a confirmation. By pressing
– To cancel the command execution press ◄.
– To quit the commands menu press ◄.

DEFAULT ALARM PROPERTIES

G
OFF
GEN
OFF
GEN
SLO
GEN
G
OFF
GEN
G
OFF
GEN
G
OFF
GEN
G
SLO
LOC
G
SLO
LOC
IMM
GEN
G
OFF
GEN
G
SLO
LOC
G
SLO
LOC
G
SLO
LOC
G
SLO
LOC
G
SLO
LOC
G
SLO
LOC
G
SLO
LOC
G
SLO
LOC
G
SLO
GEN
OFF
GEN
OFF
GEN
OFF
GEN
OFF
GEN
OFF
GEN
OFF
GEN
OFF
GEN
OFF
GEN
G
OFF
GEN
G
OFF
GEN
G
OFF
GEN
ACCESS
DESCRIPTION
LEVEL
Usr
Clears partial energy meter
Usr
Clears programmable general counters CNTx
Usr
Resets status of latched LIMx variables
Adv
Clears maximum temperature peak value
Adv
Clears maximum overload peak value
Adv
Clears hour counters of step operation
Adv
Clears counters of step switchings
Adv
Reloads originally programmed power values in step trimming
Adv
Clears total energy meters
Adv
Enables the TEST mode operation of outputs
Adv
Clears the event log memory
Adv
Resets setup programming to factory default
Adv
Makes a backup copy of user setup of parameters
Adv
Reloads parameters with the user setup backup
Usr
Clears the weekly Total Power Factor stored history
Adv
Resets the hour counting for service interval 1
Adv
Resets the hour counting for service interval 2
Adv
Resets the hour counting for service interval 3
to execute it.
again, the command is executed.
G
15
G
G
120
G
G
G
5
G
G
120
G
G
5
G
G
15
G
G
30
G
G
30
G
G
0
G
0
G
G
3
G
G
3
G
G
G
3
G
G
3
G
G
3
G
G
3
G
G
10
G
G
10
G
G
0
G
0
0
G
0
G
G
0
G
0
G
0
G
0
G
0
G
G
0
G
G
0
G
G
0
G
B

Publicidad

Tabla de contenido
loading

Tabla de contenido