5.4.5 Examples
DS-8 not used
DS-7 not used
DS-6 not used
DS-5 AES
DS-4 Inverter voltage
DS-3 Inverter frequency
DS-2 Stand-alone mode
DS-1 Stand-alone mode
stand-alone
Example 1 (factory setting):
5 AES: off
4 Inverter voltage 230V
3 Inverter frequency 50Hz
To store the settings after the dipswitches are set according to the required values:
press the 'Up' button for 2 seconds (upper button to the right of the DIP switches, see
appendix A, position J). The overload and low-battery LED's will flash to indicate
acceptance of the settings.
The DIP switches can be left in the selected positions, so that the settings can always
be recovered.
off
DS-8
off
DS-7
off
DS-6
off
DS-5
on
DS-4
on
DS-3
off
DS-2
off
DS-1
stand-alone
Example 2:
5 AES: off
4 240V
3 60Hz
off
DS-8
off
off
DS-7
off
off
DS-6
off
off
DS-5
off
off
DS-4
on
off
DS-3
off
off
DS-2
off
off
DS-1
off
stand-alone
Example 3:
5 AES: off
4 230V
3 60Hz
DS-8
off
DS-7
off
DS-6
off
DS-5
on
DS-4
off
DS-3
on
DS-2
off
DS-1
off
stand-alone
Example 4:
5 AES: on
4 240V
3 50Hz
17