4.6. Installation of the MBT5250 temperature sensor
The MBT5250 temperature probe consists of a Pt-100 sensor that converts its response in a 4/20 mA analog signal. The MBT5250 sensor
comes factory calibrated so that it is not necessary to make any process for recalibration at installation time.
Screw the MBT5250 sensor on the position labelled as "TEMP" at the body of the UV reactor.
Connect the MBT5250 sensor with the MBT-05 cable supplied with the unit to the corresponding terminals at the terminal block inside the
control box.
1.
Temperature sensor input "Temp." at the UV reactor.
2.
MBT5250 temperature sensor.
3.
MBTC-05 cable.
12
BLUE cable
13
GREEN cable
14
YELLOW cable