To change this parameter, click on the current value. A floating keyboard will appear where you must enter the new
diameter in millimeters. Press "Enter" to finish.
ACTIVATION OF FLOW-PROPORTIONAL RADIATION CONTROL
Unlike most systems in the market, HELIOX UV MP systems use two parameters when setting the lamp power, radiation
measured by UV-C sensor and flow. Thus, the system sets a nominal radiation for each model, which is determined by the
2
maximum flow of treatment to ensure a dose of 60 mJ/cm
. If the flow is less than nominal, so too will be the radiation
needed, so the systems will decrease the lamp output power, optimizing energy consumption and increasing lamp lifetime.
Like the previous models, whether radiation decreases due to loss of efficiency of the lamp, turbidity, etc., the system will
reset the lamp power.
WARNING:
In any case, the power output of the lamp will be less than 70% of its rated power.
To enable / disable flow control, click on that area. When the flow control is activated, the indicator blinks green.
FACTORY PARAMETER CONFIGURATION
The system also allows the configuration of certain operation parameters, by entering certain codes and passwords only
available for factory or technical assistance staff.
20