6.3. Replacing seals in contact with the quartz sleeve
FREQUENCY:
Replace the seals in contact with the quartz sleeve EACH TIME YOU REPLACE THE LAMP.
PROCEDURE:
To replace the seals of the quartz sleeve, proceed according to the procedure described in section 6.2.
6.4. Cleaning of the UV-C sensor
FREQUENCY:
You should check at least ONCE A YEAR that the quartz window of the UV-C sensor does not contain any type of deposit on its
surface (lime, iron, manganese, organic matter, etc.)..
In any case, clean the UV-C sensor EACH TIME YOU REPLACE THE LAMP.
PROCEDURE:
1.- Disconnect the cable of the UVC-SE sensor.
2.- Unscrew and remove the UVC-SE sensor from its housing in the body of the UV reactor.
3.- If it appears that the sensor quartz window is fully transparent, place it again in its housing as described below. If it is necessary to clean the
quartz window always do it with a soft cloth soaked with alcohol.
4.- Place and screw the UVC-SE sensor on its housing in the body of the UV reactor.
5.- Reconnect the sensor cable.
6.5. Verification of the control panel fan
FREQUENCY:
You should check the fan of the control panel, and clean up the grids and filters at least ONCE A YEAR, or if there is a noticeable
fouling thereof.
PROCEDURE:
1.- Remove the protection grids using a suitable screwdriver, as shown in the figure below.
2.- Clean and replace if necessary, the fiber filters inside.
3.- Mount again the grid in its position.
6.6. Control of system isolation and connections
FREQUENCY:
You need to check the circuit breaker located inside the control panel at least EACH TIME YOU REPLACE THE UV LAMP, by
pressing the TEST button located on its front.
You need to check the status of all connections, especially the lamp power and the grounding of both the control panel and the UV
reactor, EACH TIME YOU REPLACE THE LAMP.
23