4.2. Installation of the control panel
Always install the CONTROL PANEL of the HELIOX UV MP system vertically and on a rigid surface (wall), so that the touchscreen located on
the front panel is level with the eyes.
The HELIOX UV MP system must be connected to the electrical control box of the pool, so that the pump and the HELIOX UV MP system are
turned on (and off) simultaneously.
Warning
The equipment should be assembled and handled by truly qualified people.
Current electrical and accident prevention regulations should be followed.
Do not attempt to alter the system to operate at a different voltage.
Both the power of the HELIOX UV MP system control panel and the interconnection of the UV lamp and the sensors must be made at the
terminal block at the base inside the control panel. The control panel base has a series of cable glands for the correct fixation of the power
cables and sensors. In any case the length or section thereof should be amended, without first consulting an AstralPool authorized technician.
Control panel. Terminal block description.
MP 50 ... MP 300 models (codes 52200 to 52203)
PE
1
POWER 230 VAC / 50-60 Hz.
2
PE
UV REACTOR GROUND
3
UV LAMP OUTPUT
4
5
6
SI5004 FLOW SENSOR INPUT
7
8
9
UVC-SE RADIATION SENSOR INPUT
10
11
12
13
MBT5250 TEMPERATURE SENSOR INPUT
14
15
FLOW SWITCH INPUT
16
17
REMOTE STOP INPUT
18
MP 450 model (code 52204)
PE
1
2
POWER 380 VAC / 50-60 Hz.
3
4
PE
UV REACTOR GROUND
5
UV-1 LAMP OUTPUT
6
7
UV-2 LAMP OUTPUT
8
9
10
SI5004 FLOW SENSOR INPUT
11
12
13
UVC-SE RADIATION SENSOR INPUT
14
15
16
17
MBT5250 TEMPERATURE SENSOR INPUT
18
19
FLOW SWITCH INPUT
20
21
REMOTE STOP INPUT
22
GROUND
PHASE
NEUTRAL
GROUND
BROWN cable
BLUE cable
BROWN cable
WHITE cable
BLUE cable
WHITE cable
BRWON cable
YELLOW or BLACK cable
GREY cable
BLUE cable
GREEN cable
RED cable
POTENTIAL-FREE CONTACT
POTENTIAL-FREE CONTACT
GROUND
NEUTRAL
PHASE (R)
PHASE (S)
PHASE (T)
GROUND
BROWN cable
BLUE cable
BRWON cable
BLUE cable
BROWN cable
WHITE cable
BLUE cable
WHITE cable
BROWN cable
YELLOW or BLACK cable
GREY cable
BLUE cable
GREEN cable
RED cable
POTENTIAL-FREE CONTACT
POTENTIAL-FREE CONTACT
6
(1)
(2)
(1)
(2)

Publicidad