To do this, click on the activation code and using the pop-up keyboard, enter the code "1234".
Press the "Reset" key to confirm.
The timer will now show "0".
6.2. Cleaning / replacement of the quartz sleeve
FREQUENCY:
You should check at least ONCE A YEAR, the quartz sleeve does not contain any kind of deposit on its surface (lime, iron,
manganese, organic matter, etc.).
In any case, clean the quartz sleeve EACH TIME YOU REPLACE THE LAMP.
PROCEDURE:
EXTRACTION OF THE QUARTZ SLEEVE
1.- Follow the procedure described in Section 6.1 to remove the lamp inside the quartz sleeve.
2.- During the cleaning process of the sheath to ensure that the lamp has been placed in a safe place to keep your surface is dirty or broken.
Warning
Always handle the UV lamp with gloves, as fat and other impurities deposited on the surface
may reduce its performance and durability. In case you have to clean the lamp surface use a soft
cloth soaked with alcohol.
3.- Using the back of the Teflon cap, carefully push the quartz sleeve from one end and slide it smoothly until the O-ring on that side is released.
4.- Completely extract the lamp holding it from one of the ceramic ends, so that it does not suffer any stress.
5.- Carefully remove the O-ring on that side of the quartz sleeve.
6.- If it appears that the sleeve is completely transparent, place it again in its housing as described below.
7.- If it is necessary to clean the quartz sleeve, always do it with a soft cloth soaked with vinegar or diluted acid.
INSERTION OF THE QUARTZ SLEEVE
8.- With the help of the lever, move the cleaning mechanism of the sleeve to the right side of the reactor (viewed from the side of the sensors),
where the sleeve will be introduced.
9.- Insert the sleeve into the first disc of the cleaning device until it reaches the second cleaning disc.
10.- Move the mechanism to the other end of the reactor, and push with one hand the sleeve, guiding at all times with a finger on the other hand
so that it enters in the second cleaning disc, and trying to avoid any stress.
11.- Center the sleeve so that it sticks out equally from both sides of its housing.
12.- Lightly moisten the O-rings and put them in their original position, being slightly introduced on both sides of the sleeve.
13.- Place the end caps on the corresponding housings, and placing the palm on the cap, carefully press until the O-rings be introduced into the
sleeve. In this position, the sleeve will stick out a few millimeters above the O-ring.
14.- Reassemble the lamp as described in Section 6.1.