HIGH WATER TEMPERATURE
Whenever the temperature sensor installed in the UV reactor detects a water temperature higher than
o
45
C, the system disconnects the UV lamp and the indication of "Temperature" of the screen will flash.
CONTROL PANEL OVERHEATING:
The control panel is designed to work always at internal temperatures below 45
(excessive external temperature, failure of internal cooling fan, etc.) the temperature reaches higher
values, the system will automatically disconnect the UV lamp power leaving the internal cooling fan
running until the inside temperature drops below this value .
Overheating indicator will flash on the top of the screen.
WARNING:
Temperature control is made by the thermostat [F0] inside the control panel, so that in no case its
factory setpoint temperature (45
Once solved the problem, it is necessary to restart again the system pressing the RUN key.
ACTIVE ALARM / ALARM LOG
Whenever the system detects that an alarm is active, disconnects the UV lamp.
The system will not allow its re-initialization until the alarm condition disappears and the user makes
an acknowledgement by clicking the icon.
Clicking this icon, a list of all the alarms currently active will be visible.
17
o
C) must be modified.
If you press the button located at
the top of the menu to access the
alarm log, you can view all alarms
detected by the system from its
connection.
This register is automatically
deleted each time the system is
disconnected (only in firmware
versions prior to 11102-XXX and
11202-XXX).
To exit, simply press the arrow
keys located at the top of the
screen.
o
C. If for any reason