Malfunctions - SATA dry jet 2 Instrucciones De Servicio

Ocultar thumbs Ver también para dry jet 2:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 61
Operating instructions SATA dry jet 2
EN
■ Unscrew connection nipple
[2-5] from the air connection of
the dry jet gun [2-4].
Insert new connection nipple
■ Screw connection nipple
[2-5] onto the air connection
of the dry jet gun [2-4] (torque:
1 Nm).
10.3. Replace sieve
Remove sieve
■ Take sieve [2-1] out of the filter
holder [2-2].
Insert new sieve
Notice!
The sieve is symmetrical in de-
sign. It can be fitted in any direc-
tion.
■ Press sieve [2-1] into the filter
holder [2-2] .
10.4. Replace filter holder
Remove filter holder
■ Pull the filter holder [2-2] off the
rear nozzle [2-3] of the dry jet
gun.
Insert new filter holder
■ Push the filter holder [2-2] onto
the rear nozzle [2-3] of the dry
jet gun.
58
10.5. Clean dry jet gun
Attention!
Tool damage caused by in-
correct cleaning
The dry jet gun can be damaged
if immersed in solvent or cleaning
agent or if cleaned in an ultrasonic
cleaning machine.
→ Do not place the dry jet gun in
solvent or cleaning agent.
→ Do not clean the dry jet gun in
an ultrasonic cleaning machine.
Notice!
The dry jet gun will quickly be-
come soiled if it is not protected
from impurities during the spray-
ing process.
Notice!
The sieve is not suitable for clean-
ing and must be replaced when
clogged (see chapter 10.3).
■ Clean the dry jet gun on the
outside with a cloth soaked in
cleaning agent.

11. Malfunctions

The following table describes mal-
functions, their causes and corre-
sponding remedies.
If it is not possible to remedy the
malfunctions with the described
corrective action, send the dry jet
gun to the SATA customer service
department. (For address see
chapter 12).

Publicidad