Technical Data
Voltage .................................. ~ 230 V , 50/60 Hz .........................
Nominal acceptance power ..... 2000 W ..........................................
Gear ........................................ 1. ................... 2 . ...............................
-1
Speed (min
) ........................... 760 ................. 1 570 ...........................
Drilling diameter (Ø mm) .......... 62–162 ........... 1 0–62 .........................
Drilling range ........................... Concrete
Weight ..................................... approx. 6,7 kg ................................
Speed electronic ...................... yes .................................................
Tool fitting ................................................... outer 1.1/4" UNC, inner G 1/2"
Drill bit types ............................ SPEED STAR DX, Duramant PRO, EUROLASER, DX-HSP
Protection type ..................... IP 20 ..............................................
Noise pressure level (L
Sound power level (L
The noise level during operation can exceed 85 dB (A). Wear hearing protection!
Measured values determined in accordance with EN 60745-1.
Vibration total value .................. 3,3 m/s
The vibration level given in this information sheet has been measured in accordance with a
standardised test given in EN 60745 and may be used to compare one tool with another. It may
be used for a preliminary assessment of exposure.
The declared vibration emission level represents the main applications of the tool.
However if the tool is used for different applications, with different accessories or
insertion tools or is poorly maintained, the vibration emission may differ. This may
significantly increase the exposure level over the total working period.
An estimation of the level of exposure to vibration should also take into account the
times when the tool is switched off or when it is running but not actually doing the
job. This may significantly reduce the exposure level over the total working period.
Identify additional safety measures to protect the operator from the effects of vibra-
tion such as: maintain the tool and the accessories, keep the hands warm, organisa-
tion of work patterns.
3
Electric supply
Only connect to one-phase alternating current and to the mains voltage indicated on the power
rating plate.
3.1
Putting the PRCD switch into operation
Only suitable for AC current! Note the mains network voltage!
Perform the following test procedure on the PRCD switch before every putting into operation of
the device:
1. Connect the PRCD plug connector with the socket.
2. Press on RESET. The indicator switches to ORANGE (ON).
3. Pull the plug connector out of the socket. The display switches itself off.
14
RODIADRILL 160
max. 132 mm ................................
Masonry
max. 162 mm ................................
) ........ 91 dB (A) ¦ K
pA
) .......... 102 dB (A) ¦ K
WA
2
¦ K= 1,5 m/s
ENGLISH
RODIADRILL 200
~ 230 V , 50/60 Hz
2700 W
1. ...............2. ................ 3.
600 ............1250 ........... 3200
102–250 ....102–62 ....... 10–62
Concrete
max. 200 mm
Masonry
max. 250 mm
approx. 7,2 kg
yes
IP 20
3 dB (A)..................
92 dB (A) ¦ K
pA
3 dB (A) ...............
103 dB (A) ¦ K
WA
2
....................
4,5 m/s
3 dB (A)
pA
3 dB (A)
WA
2
2
¦ K= 1,5 m/s