SAFETY INSTRUCTIONS
When moving or relocating the air conditioner, consult experienced service
technicians for disconnection and reinstallation of the unit.
The appliance shall not be installed in the laundry.
Appliance shall be installed, operated and stored in a room with a floor area larger
than 10 m
. Mount the indoor unit at least 2.5 m above floor or grade level.
2
The installation of pipe-work shall be kept in a room with a floor area larger than
10 m
in compliance with national gas regulations.
2
ELECTRICAL WARNINGS
The power supply must be of rated voltage with special circuitry for the appliance.
The diameter of the power cord must comply with requirements.
A multi-pole switch shall be installed in the fixed wiring in accordance with the wiring
rules and the appliance must be earthed in conformity with national electrical safety
standards.
An all-pole disconnection switch having a contact separation of at least 3 mm in all
poles should be connected in fixed wiring in accordance national with wiring rules, and
the appliance must be earthed in conformity with national electrical safety standards.
Do not use extension leads, multiple sockets or adapters. The electrical components
must not be accessible to the user after installation. Do not use the appliance when you
are wet or barefoot. Do not operate this appliance if it has a damaged power cable or
plug, if it is not working properly, or if it has been damaged or dropped.
If the supply cord is damaged, it must be replaced with an identical one by the
manufacturer, its service agent or similarly qualified persons in order to avoid a hazard -
risk of electric shock.
A residual current device (RCD) having rated residual operation current not exceeding
30 mA shall be incorporated in fixed wiring according to national law.
The temperature of refrigerant circuit will be high, please keep the interconnection
cable away from the copper tube.
Ensure safe grounding and a grounding wire connected with the special grounding
system of the building, installed by professionals. The appliance must be fitted with
electrical leakage protection switch and an auxiliary circuit breaker with sufficient
capacity. The circuit breaker must also have a magnetic and a thermal tripping function
to ensure protection in case of short-circuit and overload.
Model
Required capacity of circuit breaker
For the connection of power cord and cable connection between indoor and outdoor
units, please see the wiring diagram on the appliance.

CLEANING AND MAINTENANCE

WARNING: Ensure that the appliance is switched off and disconnected from the
power supply before performing any maintenance operation; never use steam cleaning
equipment - risk of electric shock.
9K & 12K
16A
- 5 -
18K
24K
20A
25A